Title: The Influence of Supply Channel Design on the Gas-Dynamic Structure of Air Flow in a Vertical Conical Diffuser
Authors: Plotnikov, L.
Ryzhkov, A.
Issue Date: 2023
Publisher: Multidisciplinary Digital Publishing Institute (MDPI)
Citation: Plotnikov, L., & Ryzhkov, A. (2023). The Influence of Supply Channel Design on the Gas-Dynamic Structure of Air Flow in a Vertical Conical Diffuser. Applied Sciences, 13(22), [12141]. https://doi.org/10.3390/app132212141
Abstract: Vertical conical diffusers are used in power engineering, chemical industry, technological processes, and other industries. The efficiency of many machines and pieces of equipment is determined by the gas-dynamic and heat-exchange perfection of processes in diffusers. This study assesses the influence of the air supply method on flow structure in a diffuser. The studies were carried out on a test bench with thermal imaging for air flow rates ranging from 0.018 to 0.057 m3/s (42,500 < Re < 150,000). Two designs were examined: (1) a conventional air supply through one channel from below and (2) a nozzle air supply through four tubes at an angle of 45° to the vertical axis. In addition, the influence of the cross-sectional shape of the supply channels of both designs was studied. It is established that the use of a conventional air supply through one channel leads to the generation of a pronounced central flow along the vertical axis (all configurations of the supply channel) and the creation of stagnant zones in the corners of the diffuser (round and triangular channels; the use of a square supply channel causes the most uniform air distribution throughout the entire volume of the diffuser (while maintaining the central flow). It is found that with nozzle air supply, there are no stagnant zones in the corners and intense air movement generation in the centre of the diffuser (round and triangular tubes) can be observed; the use of square nozzle tubes causes intense flow movement at the base of the diffuser, which quickly collapses upstream, uniformly filling the entire volume of the diffuser’s cylindrical part. The presented data can be useful for designing various machines and pieces of equipment with vertical conical diffusers. © 2023 by the authors.
Keywords: FLOW STRUCTURE
STATIONARY GAS DYNAMICS
SUPPLY CHANNELS
THERMAL IMAGER
THERMAL IMAGING
VERTICAL DIFFUSER
URI: http://elar.urfu.ru/handle/10995/141705
Access: info:eu-repo/semantics/openAccess
cc-by
SCOPUS ID: 85192385401
WOS ID: 001109552700001
PURE ID: 49632032
ISSN: 2076-3417
DOI: 10.3390/app132212141
Sponsorship: Ministry of Education and Science of the Russian Federation, Minobrnauka
The research funding from the Ministry of Science and Higher Education of the Russian Federation (Ural Federal University Program of Development within the Priority-2030 Program) is gratefully acknowledged.
RSCF project card: Ministry of Education and Science of the Russian Federation, Minobrnauka
The research funding from the Ministry of Science and Higher Education of the Russian Federation (Ural Federal University Program of Development within the Priority-2030 Program) is gratefully acknowledged.