Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://elar.urfu.ru/handle/10995/117962
Название: | Diagnostic and therapeutic radioisotopes in nuclear medicine: Determination of gamma-ray transmission factors and safety competencies of high-dense and transparent glassy shields |
Авторы: | Erdemir, R. U. Kilic, G. Sen Baykal, D. Almisned, G. Issa, S. A. M. Zakaly, H. M. H. Ene, A. Tekin, H. O. |
Дата публикации: | 2022 |
Издатель: | De Gruyter Open Ltd |
Библиографическое описание: | Diagnostic and therapeutic radioisotopes in nuclear medicine: Determination of gamma-ray transmission factors and safety competencies of high-dense and transparent glassy shields / R. U. Erdemir, G. Kilic, D. Sen Baykal et al. // Open Chemistry. — 2022. — Vol. 20. — Iss. 1. — P. 517-524. |
Аннотация: | We present the findings of an extensive examination on newly designed CdO-rich and transparent glass shields for nuclear medicine facilities in lieu of traditional and unfavorable materials, such as lead and concrete. Gamma-ray transmission factors of newly designed glass shields are determined using a variety of diagnostic, therapeutic, and research radioisotopes, including 67Ga, 57Co, 111In, 201Tl, 99mTc, 51Cr, 131I, 58Co, 137Cs, 133Ba, and 60Co. A general-purpose Monte Carlo code MCNPX (version 2.7.0) is used to determine the attenuation parameters of different material thicknesses. Next, the findings are compared using a standard concrete shielding material. The results indicate that adding more CdO to the glass composition improves the overall gamma-ray attenuation properties. As a result, among the heavy and transparent glasses developed, the C40 sample containing 40% CdO exhibited the best gamma-ray absorption properties against all radioisotopes. Furthermore, the gamma-ray absorption characteristics of this created high-density glass were shown to be better to those of a standard and heavy concrete sample. It can be concluded that the newly developed CdO-rich and transparent glass sample may be used in medical radiation fields where the radioisotopes examined are used in daily clinical and research applications. © 2022 De Gruyter. All rights reserved. |
Ключевые слова: | GAMMA-RAY MCNPX NUCLEAR MEDICINE NUCLEAR SAFETY RADIOISOTOPES |
URI: | http://elar.urfu.ru/handle/10995/117962 |
Условия доступа: | info:eu-repo/semantics/openAccess |
Идентификатор SCOPUS: | 85133458737 |
Идентификатор WOS: | 000813846500002 |
Идентификатор PURE: | 30533130 |
ISSN: | 23915420 |
DOI: | 10.1515/chem-2022-0167 |
Сведения о поддержке: | Princess Nourah Bint Abdulrahman University, PNU: PNURSP2022R149 Funding information: This study was supported by Princess Nourah bint Abdulrahman University Researchers Supporting Project Number (PNURSP2022R149). |
Располагается в коллекциях: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
2-s2.0-85133458737.pdf | 2,35 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.