Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/117962
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorErdemir, R. U.en
dc.contributor.authorKilic, G.en
dc.contributor.authorSen Baykal, D.en
dc.contributor.authorAlmisned, G.en
dc.contributor.authorIssa, S. A. M.en
dc.contributor.authorZakaly, H. M. H.en
dc.contributor.authorEne, A.en
dc.contributor.authorTekin, H. O.en
dc.date.accessioned2022-10-19T05:20:48Z-
dc.date.available2022-10-19T05:20:48Z-
dc.date.issued2022-
dc.identifier.citationDiagnostic and therapeutic radioisotopes in nuclear medicine: Determination of gamma-ray transmission factors and safety competencies of high-dense and transparent glassy shields / R. U. Erdemir, G. Kilic, D. Sen Baykal et al. // Open Chemistry. — 2022. — Vol. 20. — Iss. 1. — P. 517-524.en
dc.identifier.issn23915420-
dc.identifier.otherhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85133458737&doi=10.1515%2fchem-2022-0167&partnerID=40&md5=4cfba00faf05d1168debed7730482e30link
dc.identifier.urihttp://elar.urfu.ru/handle/10995/117962-
dc.description.abstractWe present the findings of an extensive examination on newly designed CdO-rich and transparent glass shields for nuclear medicine facilities in lieu of traditional and unfavorable materials, such as lead and concrete. Gamma-ray transmission factors of newly designed glass shields are determined using a variety of diagnostic, therapeutic, and research radioisotopes, including 67Ga, 57Co, 111In, 201Tl, 99mTc, 51Cr, 131I, 58Co, 137Cs, 133Ba, and 60Co. A general-purpose Monte Carlo code MCNPX (version 2.7.0) is used to determine the attenuation parameters of different material thicknesses. Next, the findings are compared using a standard concrete shielding material. The results indicate that adding more CdO to the glass composition improves the overall gamma-ray attenuation properties. As a result, among the heavy and transparent glasses developed, the C40 sample containing 40% CdO exhibited the best gamma-ray absorption properties against all radioisotopes. Furthermore, the gamma-ray absorption characteristics of this created high-density glass were shown to be better to those of a standard and heavy concrete sample. It can be concluded that the newly developed CdO-rich and transparent glass sample may be used in medical radiation fields where the radioisotopes examined are used in daily clinical and research applications. © 2022 De Gruyter. All rights reserved.en
dc.description.sponsorshipPrincess Nourah Bint Abdulrahman University, PNU: PNURSP2022R149en
dc.description.sponsorshipFunding information: This study was supported by Princess Nourah bint Abdulrahman University Researchers Supporting Project Number (PNURSP2022R149).en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherDe Gruyter Open Ltden
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.sourceOpen Chemistryen
dc.subjectGAMMA-RAYen
dc.subjectMCNPXen
dc.subjectNUCLEAR MEDICINEen
dc.subjectNUCLEAR SAFETYen
dc.subjectRADIOISOTOPESen
dc.titleDiagnostic and therapeutic radioisotopes in nuclear medicine: Determination of gamma-ray transmission factors and safety competencies of high-dense and transparent glassy shieldsen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.1515/chem-2022-0167-
dc.identifier.scopus85133458737-
local.contributor.employeeErdemir, R.U., Department of Nuclear Medicine, Zonguldak Bulent Ecevit University of Medicine, Zonguldak, Turkeyen
local.contributor.employeeKilic, G., Department of Physics, Eskisehir Osmangazi University, Faculty of Science and Letters, Eskisehir, Turkeyen
local.contributor.employeeSen Baykal, D., Istanbul Kent University, Vocational School of Health Sciences, Department of Medical Imaging Techniques, Istanbul, 34433, Turkeyen
local.contributor.employeeAlmisned, G., Department of Physics, College of Science, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh, 11671, Saudi Arabiaen
local.contributor.employeeIssa, S.A.M., Physics Department, Faculty of Science, University of Tabuk, Tabuk, 47512, Saudi Arabia, Physics Department, Faculty of Science, Al-Azhar University, Assiut, 71524, Egypten
local.contributor.employeeZakaly, H.M.H., Physics Department, Faculty of Science, Al-Azhar University, Assiut, 71524, Egypt, Institute of Physics and Technology, Ural Federal University, Ekaterinburg, 620002, Russian Federationen
local.contributor.employeeEne, A., Department of Chemistry, Physics and Environment, INPOLDE Research Center, Faculty of Sciences and Environment, Dunarea de Jos University of Galati, 47 Domneasca Street, Galati, 800008, Romaniaen
local.contributor.employeeTekin, H.O., Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah, 27272, United Arab Emirates, Computer Engineering Department, Istinye University, Faculty of Engineering and Natural Sciences, Istanbul, 34396, Turkeyen
local.description.firstpage517-
local.description.lastpage524-
local.issue1-
local.volume20-
dc.identifier.wos000813846500002-
local.contributor.departmentDepartment of Nuclear Medicine, Zonguldak Bulent Ecevit University of Medicine, Zonguldak, Turkeyen
local.contributor.departmentDepartment of Physics, Eskisehir Osmangazi University, Faculty of Science and Letters, Eskisehir, Turkeyen
local.contributor.departmentIstanbul Kent University, Vocational School of Health Sciences, Department of Medical Imaging Techniques, Istanbul, 34433, Turkeyen
local.contributor.departmentDepartment of Physics, College of Science, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh, 11671, Saudi Arabiaen
local.contributor.departmentPhysics Department, Faculty of Science, University of Tabuk, Tabuk, 47512, Saudi Arabiaen
local.contributor.departmentPhysics Department, Faculty of Science, Al-Azhar University, Assiut, 71524, Egypten
local.contributor.departmentInstitute of Physics and Technology, Ural Federal University, Ekaterinburg, 620002, Russian Federationen
local.contributor.departmentDepartment of Chemistry, Physics and Environment, INPOLDE Research Center, Faculty of Sciences and Environment, Dunarea de Jos University of Galati, 47 Domneasca Street, Galati, 800008, Romaniaen
local.contributor.departmentDepartment of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah, 27272, United Arab Emiratesen
local.contributor.departmentComputer Engineering Department, Istinye University, Faculty of Engineering and Natural Sciences, Istanbul, 34396, Turkeyen
local.identifier.pure30533130-
local.identifier.eid2-s2.0-85133458737-
local.identifier.wosWOS:000813846500002-
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85133458737.pdf2,35 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.