Please use this identifier to cite or link to this item: http://elar.urfu.ru/handle/10995/92379
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKhalyasmaa, A. I.en
dc.contributor.authorSultonov, S. M.en
dc.contributor.authorAhyoev, J. S.en
dc.contributor.authorBahovadinov, A. H.en
dc.date.accessioned2020-10-20T16:35:32Z-
dc.date.available2020-10-20T16:35:32Z-
dc.date.issued2020-
dc.identifier.citationKhalyasmaa A. I. Vibration problem solution of high-capacity hydropower units / A. I. Khalyasmaa, S. M. Sultonov, J. S. Ahyoev, A. H. Bahovadinov. — DOI 10.1088/1757-899X/836/1/012009 // IOP Conference Series: Materials Science and Engineering. — 2020. — Vol. 1. — Iss. 836. — 12009.en
dc.identifier.issn17578981-
dc.identifier.otherhttps://doi.org/10.1088/1757-899x/836/1/012009pdf
dc.identifier.other1good_DOI
dc.identifier.other69a61ab9-a1f8-4349-8995-032860a42706pure_uuid
dc.identifier.otherhttp://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85085750192m
dc.identifier.urihttp://elar.urfu.ru/handle/10995/92379-
dc.description.abstractThis paper proposes hydro generator vibration observations under various conditions and solution of a problem of high vibration in upper guide bearing of 110MW hydro generator. Among the test, which were carried out to identify vibration origin of hydro generating unit were: Voltage drop tests, magnetic flux measurements, interferric gap measurements, turbine pressure pulsation measurements, etc. It was shown, that among other possible reasons, correct balancing, including pivot bearing adjustment was the most efficient measure to eliminate vibration in start-up modes of hydro power unit. According to the results of conducted step-by-step defect analysis, the corresponding recommendations were provided for service and maintenance regarding the generation unit No2 of Sangtuda-2 Hydro Power Plant, Tajikistan. © Published under licence by IOP Publishing Ltd.en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherInstitute of Physics Publishingen
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.sourceIOP Conference Series: Materials Science and Engineeringen
dc.titleVibration problem solution of high-capacity hydropower unitsen
dc.typeConference Paperen
dc.typeinfo:eu-repo/semantics/conferenceObjecten
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.1088/1757-899X/836/1/012009-
dc.identifier.scopus85085750192-
local.affiliationUral Federal University, Ekaterinburg, Russian Federation
local.affiliationTajik Technical University, Department of Power Stations, Dushanbe, Tajikistan
local.affiliationSangtuda-2 Hpp, Engineering and Maintenance Department, Tajikistan
local.contributor.employeeKhalyasmaa, A.I., Ural Federal University, Ekaterinburg, Russian Federation
local.contributor.employeeSultonov, S.M., Tajik Technical University, Department of Power Stations, Dushanbe, Tajikistan
local.contributor.employeeAhyoev, J.S., Tajik Technical University, Department of Power Stations, Dushanbe, Tajikistan
local.contributor.employeeBahovadinov, A.H., Sangtuda-2 Hpp, Engineering and Maintenance Department, Tajikistan
local.issue836-
local.volume1-
dc.identifier.wos000562928800009-
local.identifier.pure13148701-
local.description.order12009-
local.identifier.eid2-s2.0-85085750192-
local.identifier.wosWOS:000562928800009-
Appears in Collections:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Files in This Item:
File Description SizeFormat 
10.1088-1757-899X-836-1-012009.pdf802,75 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.