Please use this identifier to cite or link to this item: http://elar.urfu.ru/handle/10995/75703
Title: Magnetoimpedance Effect in the Ribbon-Based Patterned Soft Ferromagnetic Meander-Shaped Elements for Sensor Application
Authors: Yang, Z.
Chlenova, A. A.
Golubeva, E. V.
Volchkov, S. O.
Guo, P.
Shcherbinin, S. V.
Kurlyandskaya, G. V.
Issue Date: 2019
Publisher: NLM (Medline)
Citation: Magnetoimpedance Effect in the Ribbon-Based Patterned Soft Ferromagnetic Meander-Shaped Elements for Sensor Application / Z. Yang, A. A. Chlenova, E. V. Golubeva et al. // Sensors (Basel, Switzerland). — 2019. — Vol. 19. — Iss. 11
Abstract: Amorphous and nanocrystalline soft magnetic materials have attracted much attention in the area of sensor applications. In this work, the magnetoimpedance (MI) effect of patterned soft ferromagnetic meander-shaped sensor elements has been investigated. They were fabricated starting from the cobalt-based amorphous ribbon using the lithography technique and chemical etching. Three-turn (S1: spacing s = 50 μm, width w = 300 μm, length l = 5 mm; S2: spacing s = 50 μm, width w = 400 μm, length l = 5 mm) and six-turn (S3: s = 40 μm, w = 250 μm, length l = 5 mm; S4: s = 40 μm, w = 250 μm and l = 8 mm) meanders were designed. The 'n' shaped meander part was denominated as "one turn". The S4 meander possesses a maximum MI ratio calculated for the total impedance ΔZ/Z ≈ 250% with a sensitivity of about 36%/Oe (for the frequency of about 45 MHz), and an MI ratio calculated for the real part of the total impedance ΔR/R ≈ 250% with the sensitivity of about 32%/Oe (for the frequency of 50 MHz). Chemical etching and the length of the samples had a strong impact on the surface magnetic properties and the magnetoimpedance. A comparative analysis of the surface magnetic properties obtained by the magneto-optical Kerr technique and MI data shows that the designed ferromagnetic meander-shaped sensor elements can be recommended for high frequency sensor applications focused on the large drop analysis. Here we understand a single large drop as the water-based sample to analyze, placed onto the surface of the MI sensor element either by microsyringe (volue range 0.5-500 μL) or automatic dispenser (volume range 0.1-50 mL).
Keywords: AMORPHOUS RIBBONS
MAGNETIC FIELD SENSOR
MAGNETOIMPEDANCE EFFECT
MEANDER SENSITIVE ELEMENT
PATTERNED RIBBONS
URI: http://elar.urfu.ru/handle/10995/75703
Access: info:eu-repo/semantics/openAccess
SCOPUS ID: 85066922665
WOS ID: 000472133300046
PURE ID: 10001586
ISSN: 1424-8220
DOI: 10.3390/s19112468
Appears in Collections:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Files in This Item:
File Description SizeFormat 
2-s2.0-85066922665.pdf3,37 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.