Please use this identifier to cite or link to this item: http://elar.urfu.ru/handle/10995/132350
Title: Study of Defects of Longitudinal Welded Pipe
Authors: Shleenkov, A. S.
Novgorodov, D. V.
Konovalchuk, V. O.
Issue Date: 2022
Publisher: American Institute of Physics Inc.
Citation: Shleenkov, AS, Novgorodov, DV & Konovalchuk, VO 2022, Study of Defects of Longitudinal Welded Pipe. в S Bratan & S Roshchupkin (ред.), International Conference on Modern Trends in Manufacturing Technologies and Equipment 2021, ICMTMTE 2021., 050080, AIP Conference Proceedings, Том. 2503, American Institute of Physics Inc., International Conference on Modern Trends in Manufacturing Technologies and Equipment 2021, ICMTMTE 2021, Sevastopol, Российская Федерация, 06/09/2021. https://doi.org/10.1063/5.0099909
Shleenkov, A. S., Novgorodov, D. V., & Konovalchuk, V. O. (2022). Study of Defects of Longitudinal Welded Pipe. в S. Bratan, & S. Roshchupkin (Ред.), International Conference on Modern Trends in Manufacturing Technologies and Equipment 2021, ICMTMTE 2021 [050080] (AIP Conference Proceedings; Том 2503). American Institute of Physics Inc.. https://doi.org/10.1063/5.0099909
Abstract: During the production of longitudinal electric welds by the method of high-frequency welding (HFW), defects of the longitudinal weld were revealed using X-ray inspection. For these defects, metallographic analysis was carried out, which showed that both the base metal and the welded joint met the requirements of regulatory documents. The chemical composition and mechanical properties also comply with the requirements of regulatory documents. Non-metallic inclusions of the liquation strips of the sheet, emerging on the edge and falling into the welding zone, were detected during X-ray inspection and were not correctly identified as a defect. This assumption is based on the coincidence of the position of the "grooves" in the zones of the welded joint with X-ray diffraction patterns, while the defects are not confirmed by other control methods and metallographic studies. Incorrect interpretation of defects during X-ray inspection occurs in the production of pipes [1-4] and requires additional verification or duplicate inspection. © 2022 American Institute of Physics Inc.. All rights reserved.
URI: http://elar.urfu.ru/handle/10995/132350
Access: info:eu-repo/semantics/openAccess
Conference name: 6 September 2021 through 10 September 2021
Conference date: International Conference on Modern Trends in Manufacturing Technologies and Equipment 2021, ICMTMTE 2021
SCOPUS ID: 85140342989
PURE ID: 1cb1589b-ff31-4291-8447-6cb4cd27e0fc
31573010
ISSN: 0094-243X
ISBN: 978-073544221-4
DOI: 10.1063/5.0099909
metadata.dc.description.sponsorship: Minobrnauki of Russia, (ȺȺȺȺ-Ⱥ -118020690196-3)
Russian Foundation for Basic Research, РФФИ, (18-38-00253)
The research was carried out within the state assignment of Minobrnauki of Russia (theme “Diagnostics” No. ȺȺȺȺ-Ⱥ -118020690196-3), supported in part by RFBR (project No. 18-38-00253).
Appears in Collections:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Files in This Item:
File Description SizeFormat 
2-s2.0-85140342989.pdf1,03 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.