Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/130983
Название: STEPS TOWARD OPTIMIZING HPGe DETECTOR EFFICIENCY IN THE CONTEXT OF LOW-LEVEL RADIOACTIVITY DETECTION
Авторы: Aziz, D. A.
Saudi, H. A.
Zakaly, H. M. H.
El-Melegy, W.
Diab, H. M.
Дата публикации: 2023
Издатель: Publishing House of the Romanian Academy
Библиографическое описание: Aziz, DA, Saudi, HA, Zakaly, HMH, El-Melegy, W & Diab, HM 2023, 'STEPS TOWARD OPTIMIZING HPGe DETECTOR EFFICIENCY IN THE CONTEXT OF LOW-LEVEL RADIOACTIVITY DETECTION', Romanian Journal of Physics, Том. 68, № 9, 305. https://doi.org/10.59277/RomJPhys.2023.68.305
Aziz, D. A., Saudi, H. A., Zakaly, H. M. H., El-Melegy, W., & Diab, H. M. (2023). STEPS TOWARD OPTIMIZING HPGe DETECTOR EFFICIENCY IN THE CONTEXT OF LOW-LEVEL RADIOACTIVITY DETECTION. Romanian Journal of Physics, 68(9), [305]. https://doi.org/10.59277/RomJPhys.2023.68.305
Аннотация: Different empirical and theoretical methods are used to precisely determine radionuclide activity concentrations. This study used Monte Carlo simulation MCNP5 code and EFFTRAN software (Efficiency Transfer) to determine the HPGe detector Full-Energy Peak (FEP) efficiency. A set of point sources (133Ba,152Eu,137Cs,60Co, and22Na) fixed on the top of the standard geometry plastic container were measured in order to obtain the calibration curve. Because of the importance of chemical composition parameters, the detector behavior due to different matrices was investigated. Experimental verification of the calibration was obtained using IAEA-TEL-2021-03 quality control water sample spiked with152Eu and133Ba, and the results were compared with reported results. A set of Certified Standard Reference samples were used for method validation. The obtained results were compared with the experimental results. The comparison clarified the advantages and disadvantages of both methods and their precision to demonstrate and suitable method for matrix types. © 2023, Publishing House of the Romanian Academy. All rights reserved.
Ключевые слова: EFFTRAN
GAMMA SPECTROMETRY
HPGE EFFICIENCY CALIBRATION
MONTE CARLO
RADIOACTIVITY
URI: http://elar.urfu.ru/handle/10995/130983
Условия доступа: info:eu-repo/semantics/openAccess
Идентификатор SCOPUS: 85177203782
Идентификатор WOS: 001111359700014
Идентификатор PURE: 48558088
ISSN: 1221-146X
DOI: 10.59277/RomJPhys.2023.68.305
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85177203782.pdf442,99 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.