Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/130983
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorAziz, D. A.en
dc.contributor.authorSaudi, H. A.en
dc.contributor.authorZakaly, H. M. H.en
dc.contributor.authorEl-Melegy, W.en
dc.contributor.authorDiab, H. M.en
dc.date.accessioned2024-04-05T16:36:42Z-
dc.date.available2024-04-05T16:36:42Z-
dc.date.issued2023-
dc.identifier.citationAziz, DA, Saudi, HA, Zakaly, HMH, El-Melegy, W & Diab, HM 2023, 'STEPS TOWARD OPTIMIZING HPGe DETECTOR EFFICIENCY IN THE CONTEXT OF LOW-LEVEL RADIOACTIVITY DETECTION', Romanian Journal of Physics, Том. 68, № 9, 305. https://doi.org/10.59277/RomJPhys.2023.68.305harvard_pure
dc.identifier.citationAziz, D. A., Saudi, H. A., Zakaly, H. M. H., El-Melegy, W., & Diab, H. M. (2023). STEPS TOWARD OPTIMIZING HPGe DETECTOR EFFICIENCY IN THE CONTEXT OF LOW-LEVEL RADIOACTIVITY DETECTION. Romanian Journal of Physics, 68(9), [305]. https://doi.org/10.59277/RomJPhys.2023.68.305apa_pure
dc.identifier.issn1221-146X-
dc.identifier.otherFinal2
dc.identifier.otherAll Open Access, Bronze3
dc.identifier.otherhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85177203782&doi=10.59277%2fRomJPhys.2023.68.305&partnerID=40&md5=807fdeca1ff9d0bd3ff7a3f972af1c511
dc.identifier.otherhttps://doi.org/10.59277/romjphys.2023.68.305pdf
dc.identifier.urihttp://elar.urfu.ru/handle/10995/130983-
dc.description.abstractDifferent empirical and theoretical methods are used to precisely determine radionuclide activity concentrations. This study used Monte Carlo simulation MCNP5 code and EFFTRAN software (Efficiency Transfer) to determine the HPGe detector Full-Energy Peak (FEP) efficiency. A set of point sources (133Ba,152Eu,137Cs,60Co, and22Na) fixed on the top of the standard geometry plastic container were measured in order to obtain the calibration curve. Because of the importance of chemical composition parameters, the detector behavior due to different matrices was investigated. Experimental verification of the calibration was obtained using IAEA-TEL-2021-03 quality control water sample spiked with152Eu and133Ba, and the results were compared with reported results. A set of Certified Standard Reference samples were used for method validation. The obtained results were compared with the experimental results. The comparison clarified the advantages and disadvantages of both methods and their precision to demonstrate and suitable method for matrix types. © 2023, Publishing House of the Romanian Academy. All rights reserved.en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherPublishing House of the Romanian Academyen
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.sourceRomanian Journal of Physics2
dc.sourceRomanian Journal of Physicsen
dc.subjectEFFTRANen
dc.subjectGAMMA SPECTROMETRYen
dc.subjectHPGE EFFICIENCY CALIBRATIONen
dc.subjectMONTE CARLOen
dc.subjectRADIOACTIVITYen
dc.titleSTEPS TOWARD OPTIMIZING HPGe DETECTOR EFFICIENCY IN THE CONTEXT OF LOW-LEVEL RADIOACTIVITY DETECTIONen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.type|info:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.59277/RomJPhys.2023.68.305-
dc.identifier.scopus85177203782-
local.contributor.employeeAziz, D.A., Radiation Protection Department, Nuclear and Radiation Safety Center, Egyptian Atomic Energy Authority, Nasr City, Egypten
local.contributor.employeeSaudi, H.A., Department of Physics, Faculty of Science, Al-Azhar University ('Girls' Branch), Nasr City, Egypten
local.contributor.employeeZakaly, H.M.H., Institute of Physics and Technology, Ural Federal University, Yekaterinburg, 620002, Russian Federation, Department of Physics, Faculty of Science, Al-Azhar University, Assiut Branch71524, Egypten
local.contributor.employeeEl-Melegy, W., Department of Physics, Faculty of Science, Al-Azhar University ('Girls' Branch), Nasr City, Egypten
local.contributor.employeeDiab, H.M., Radiation Protection Department, Nuclear and Radiation Safety Center, Egyptian Atomic Energy Authority, Nasr City, Egypten
local.issue9-10-
local.volume68-
dc.identifier.wos001111359700014-
local.contributor.departmentRadiation Protection Department, Nuclear and Radiation Safety Center, Egyptian Atomic Energy Authority, Nasr City, Egypten
local.contributor.departmentDepartment of Physics, Faculty of Science, Al-Azhar University ('Girls' Branch), Nasr City, Egypten
local.contributor.departmentInstitute of Physics and Technology, Ural Federal University, Yekaterinburg, 620002, Russian Federationen
local.contributor.departmentDepartment of Physics, Faculty of Science, Al-Azhar University, Assiut Branch71524, Egypten
local.identifier.pure48558088-
local.description.order305-
local.identifier.eid2-s2.0-85177203782-
local.identifier.wosWOS:001111359700014-
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85177203782.pdf442,99 kBAdobe PDFПросмотреть/Открыть