Please use this identifier to cite or link to this item: http://elar.urfu.ru/handle/10995/130565
Title: The importance of mechanical conditions in the testing of excitation abnormalities in a population of electro-mechanical models of human ventricular cardiomyocytes
Authors: Dokuchaev, A.
Kursanov, A.
Balakina-Vikulova, N. A.
Katsnelson, L. B.
Solovyova, O.
Issue Date: 2023
Publisher: Frontiers Media SA
Citation: Dokuchaev, A, Kursanov, A, Balakina-Vikulova, NA, Katsnelson, LB & Solovyova, O 2023, 'The importance of mechanical conditions in the testing of excitation abnormalities in a population of electro-mechanical models of human ventricular cardiomyocytes', Frontiers in Physiology, Том. 14, 1187956. https://doi.org/10.3389/fphys.2023.1187956
Dokuchaev, A., Kursanov, A., Balakina-Vikulova, N. A., Katsnelson, L. B., & Solovyova, O. (2023). The importance of mechanical conditions in the testing of excitation abnormalities in a population of electro-mechanical models of human ventricular cardiomyocytes. Frontiers in Physiology, 14, [1187956]. https://doi.org/10.3389/fphys.2023.1187956
Abstract: Background: Populations of in silico electrophysiological models of human cardiomyocytes represent natural variability in cell activity and are thoroughly calibrated and validated using experimental data from the human heart. The models have been shown to predict the effects of drugs and their pro-arrhythmic risks. However, excitation and contraction are known to be tightly coupled in the myocardium, with mechanical loads and stretching affecting both mechanics and excitation through mechanisms of mechano-calcium-electrical feedback. However, these couplings are not currently a focus of populations of cell models. Aim: We investigated the role of cardiomyocyte mechanical activity under different mechanical conditions in the generation, calibration, and validation of a population of electro-mechanical models of human cardiomyocytes. Methods: To generate a population, we assumed 11 input parameters of ionic currents and calcium dynamics in our recently developed TP + M model as varying within a wide range. A History matching algorithm was used to generate a non-implausible parameter space by calibrating the action potential and calcium transient biomarkers against experimental data and rejecting models with excitation abnormalities. The population was further calibrated using experimental data on human myocardial force characteristics and mechanical tests involving variations in preload and afterload. Models that passed the mechanical tests were validated with additional experimental data, including the effects of drugs with high or low pro-arrhythmic risk. Results: More than 10% of the models calibrated on electrophysiological data failed mechanical tests and were rejected from the population due to excitation abnormalities at reduced preload or afterload for cell contraction. The final population of accepted models yielded action potential, calcium transient, and force/shortening outputs consistent with experimental data. In agreement with experimental and clinical data, the models demonstrated a high frequency of excitation abnormalities in simulations of Dofetilide action on the ionic currents, in contrast to Verapamil. However, Verapamil showed a high frequency of failed contractions at high concentrations. Conclusion: Our results highlight the importance of considering mechanoelectric coupling in silico cardiomyocyte models. Mechanical tests allow a more thorough assessment of the effects of interventions on cardiac function, including drug testing. Copyright © 2023 Dokuchaev, Kursanov, Balakina-Vikulova, Katsnelson and Solovyova.
Keywords: CARDIAC ELECTROPHYSIOLOGY
DRUG TESTING
HUMAN VENTRICULAR CARDIOMYOCYTE
MATHEMATICAL MODELS
MECHANICAL FUNCTION
REPOLARIZATION ABNORMALITIES
ADENOSINE TRIPHOSPHATASE (POTASSIUM SODIUM)
CALCIUM
DOFETILIDE
POTASSIUM
SODIUM
SODIUM CALCIUM EXCHANGE PROTEIN
VERAPAMIL
ACTION POTENTIAL
ALGORITHM
APD90
ARTICLE
CARDIAC MUSCLE CELL
CD50 (CYTOTOXIC DOSE)
ELECTROMECHANICAL MODEL
HEART ARRHYTHMIA
HEART CONTRACTION
HEART ELECTROPHYSIOLOGY
HEART FUNCTION
HUMAN
IC50
ION CURRENT
MECHANICAL TEST
MEMBRANE STEADY POTENTIAL
MODEL
PATCH CLAMP TECHNIQUE
QT INTERVAL
SARCOMERE LENGTH
URI: http://elar.urfu.ru/handle/10995/130565
Access: info:eu-repo/semantics/openAccess
cc-by
License text: https://creativecommons.org/licenses/by/4.0/
SCOPUS ID: 85162692140
WOS ID: 001014999200001
PURE ID: 41534307
ISSN: 1664-042X
DOI: 10.3389/fphys.2023.1187956
metadata.dc.description.sponsorship: Russian Science Foundation, RSF: 19-14-00134
This work was supported by Russian Science Foundation grant No. 19-14-00134.
RSCF project card: 19-14-00134
Appears in Collections:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Files in This Item:
File Description SizeFormat 
2-s2.0-85162692140.pdf35,81 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons