Название: Mathematical modeling of a hybrid ventilation system with a technical floor
Авторы: Nekrasov, A. V.
Дата публикации: 2023
Издатель: American Institute of Physics Inc.
Библиографическое описание: Nekrasov, AV 2023, Mathematical modeling of a hybrid ventilation system with a technical floor. в L Boswell, V Alekhin & A Nazarov (ред.), VII International Conference “Safety Problems of Civil Engineering Critical Infrastructures” (SPCECI2021): Conference Proceeding. Том. 2701, 020024, AIP Conference Proceedings, № 1, Том. 2701, American Institute of Physics Inc. https://doi.org/10.1063/5.0120976
Nekrasov, A. V. (2023). Mathematical modeling of a hybrid ventilation system with a technical floor. в L. Boswell, V. Alekhin, & A. Nazarov (Ред.), VII International Conference “Safety Problems of Civil Engineering Critical Infrastructures” (SPCECI2021): Conference Proceeding (Том 2701). [020024] (AIP Conference Proceedings; Том 2701, № 1). American Institute of Physics Inc.. https://doi.org/10.1063/5.0120976
Аннотация: The results of the analysis of the design of the ventilation system of a section of a ten-story residential building, including three- and one-room apartments, using a mathematical model are presented. The equations of the ventilation system model are based on the hydraulic network graph. The model includes equations for the balance of air flow rates for the nodes of the graph and equations for changing the pressure for the links. It is shown that it is impossible to provide the required air flow rates simultaneously in all apartments using natural ventilation, including in the presence of wind. The model allows you to compare different ways to improve the performance of the ventilation system. As an example, two options for using exhaust fans that remove air from an attic space (hybrid ventilation) are considered. When using one fan, the mode of its operation is determined by the apartments, the windows of which are into the area of the aerodynamic shadow. As a result, the ventilation air rate in other apartments can significantly exceed the required ones. To improve the uniformity of air exchange, it is advisable to combine the ventilation ducts of apartments, oriented mainly at one building facade, into separate zones, each of which is served by its own fan. © 2023 Author(s).
URI: http://elar.urfu.ru/handle/10995/130328
Условия доступа: info:eu-repo/semantics/openAccess
Конференция/семинар: 7th International Conference on Safety Problems of Civil Engineering Critical Infrastructures, SPCECI 2021
Дата конференции/семинара: 27 May 2021 through 28 May 2021
Идентификатор SCOPUS: 85151320218
Идентификатор PURE: 37096902
ISSN: 0094-243X
ISBN: 9780735444157
DOI: 10.1063/5.0120976
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85151320218.pdf858,02 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.