Please use this identifier to cite or link to this item:
http://elar.urfu.ru/handle/10995/130224
Title: | Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings |
Authors: | ALMisned, G. Elshami, W. Kilic, G. Ilik, E. Rabaa, E. Zakaly, H. M. H. Ene, A. Tekin, H. O. |
Issue Date: | 2023 |
Publisher: | MDPI |
Citation: | Almisned, G, Elshami, W, Kilic, G, Ilik, E, Rabaa, E, Zakaly, HMH, Ene, A & Tekin, HO 2023, 'Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings', Medicina, Том. 59, № 2, 327. https://doi.org/10.3390/medicina59020327 Almisned, G., Elshami, W., Kilic, G., Ilik, E., Rabaa, E., Zakaly, H. M. H., Ene, A., & Tekin, H. O. (2023). Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings. Medicina, 59(2), [327]. https://doi.org/10.3390/medicina59020327 |
Abstract: | Background: During mammography, a lead-acrylic protective screen is recommended to reduce radiation exposure to the unexposed breast. Objectives: This research study aimed to construct an Indium-(III)-oxide-rich tellurite-glass screen (TZI8) and compare its performance to that of lead acrylic. Materials and Methods: A three-layer heterogeneous-breast phantom was developed, using the MCNPX (version 2.7.0) Monte Carlo code. An MCNPX-simulation geometry was designed and implemented, using the lead-acrylic and TZI8 shielding screens between the right and left breast. Next, the reliability of the phantom and the variations in absorption between the lead-acrylic and TZI8 glass were investigated. Results: The findings show that the TZI8-protective-glass screen offers significantly greater radioprotection than the lead-acrylic material. The quantity of total dose absorbed in the unexposed breast was much lower for TZI8 than for lead-based acrylic. The TZI8-glass screen gives about 60% more radioprotection than the lead-acrylic screen. Conclusion: Considering the toxic lead in the structure that may be hazardous to the human tissues, the TZI8-glass screen may be used in mammography examination to provide greater radioprotection than the lead-acrylic screen, in order to greatly reduce the dose to the unexposed breast. © 2023 by the authors. |
Keywords: | BREAST DOSIMETRY MAMMOGRAPHY RADIATION PROTECTION X-RAY |
URI: | http://elar.urfu.ru/handle/10995/130224 |
Access: | info:eu-repo/semantics/openAccess cc-by |
License text: | https://creativecommons.org/licenses/by/4.0/ |
SCOPUS ID: | 85148883724 |
WOS ID: | 000941566600001 |
PURE ID: | 35500063 |
ISSN: | 1010-660X |
DOI: | 10.3390/medicina59020327 |
Sponsorship: | Princess Nourah Bint Abdulrahman University, PNU: PNURSP2023R149; Deanship of Scientific Research, King Khalid University: G.R.P.1-27-43 The authors would like to express their deepest gratitude to Princess Nourah bint Abdulrahman University Researchers Supporting Project number (PNURSP2023R149), Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia. The authors extend their gratitude to the King Khalid University Deanship of Scientific Research for funding this project through the General Research Project under the grant number (G.R.P.1-27-43). |
Appears in Collections: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2-s2.0-85148883724.pdf | 3,44 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License