Title: Neutron Dosimetry at Workplaces of Jc “Institute of Nuclear Materials”
Authors: Pyshkina, M. D.
Vasilyev, A. V.
Ekidin, A. A.
Nazarov, E. I.
Romanova, M. A.
Gurinovich, V. I.
Komar, D. I.
Kozhemyakin, V. A.
Issue Date: 2021
Publisher: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
SPRI of Radiation Hygiene Prof. PV Ramzaev
Citation: Neutron Dosimetry at Workplaces of Jc “Institute of Nuclear Materials” / M. D. Pyshkina, A. V. Vasilyev, A. A. Ekidin et al. // Radiatsionnaya Gygiena. — 2021. — Vol. 14. — Iss. 2. — P. 89-99.
Abstract: If the neutron fields at personnel workplaces differ from the neutron fields in which individual dosimeters are verified, there is a possibility of additional errors in the assessment of such dosimetric quantities as ambient dose equivalent, individual dose equivalent or effective dose. To take into account the energy distribution of the neutron radiation flux density and the geometry of the irradiation of workers, it is necessary to study the characteristics of the fields of neutron radiation at the workplaces of the personnel. In order to obtain conditionally true levels of personnel exposure to neutron radiation at nuclear facilities, studies of the energy and angular distribution of the neutron radiation flux density were carried out at the workplaces of the Institute of Reactor Materials JSC, Zarechny. The energy distribution of the neutron radiation flux density was obtained using an MKS-AT1117M multi-sphere dosimeter-radiometer with a BDKN-06 detection unit and a set of polyethylene spheres-moderators. The angular distribution of the neutron radiation flux density was estimated from the results of measurements of the accumulated dose of neutron radiation by individual thermolumines-cent dosimeters placed on four vertical planes of a heterogeneous human phantom. The results of measurements of the energy and angular distribution of the neutron radiation flux density made it possible to estimate the conditionally true values of the ambient and individual dose equivalents. The calculated conventionally true values differ from the measured values from 0.7 to 8.9 times for the ambient dose equivalent and from 6 to 50 times for the individual dose equivalent. In order to reduce the error in assessing the effective dose of personnel using personal dosimeters, correction factors were determined. For different workplaces and types of personal dosimeters, correction factors are in the range of values from 0.02 to 0.16. © 2021, Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev. All rights reserved.
Keywords: CORRECTION FACTOR
DOSIMETER-RADIOMETER
EXPOSURE GEOMETRY
NEUTRONS
POLYETHYLENE
ARTICLE
DOSIMETRY
GEOMETRY
HUMAN
NEUTRON DOSIMETRY
NEUTRON RADIATION
RADIATION DOSE
RADIATION EXPOSURE
WORKPLACE
URI: http://elar.urfu.ru/handle/10995/111559
Access: info:eu-repo/semantics/openAccess
RSCI ID: 46289499
SCOPUS ID: 85110507748
PURE ID: 22845148
ISSN: 1998-426X
DOI: 10.21514/1998-426X-2021-14-2-89-99
metadata.dc.description.sponsorship: Работа выполнена при поддержке гранта Президента Российской Федерации (грант № МК-4027.2021.4) и при финансовой поддержке РФФИ в рамках научного проекта № 19-38-90096.
Appears in Collections:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Files in This Item:
File Description SizeFormat 
2-s2.0-85110507748.pdf1,31 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.