Please use this identifier to cite or link to this item:
http://elar.urfu.ru/handle/10995/102745
Title: | The CO2 absorption continuum by high pressure CRDS in the 1.74 µm window |
Authors: | Mondelain, D. Campargue, A. Čermák, P. Gamache, R. R. Kassi, S. Tashkun, S. A. Tran, H. |
Issue Date: | 2017 |
Publisher: | Elsevier Ltd |
Citation: | The CO2 absorption continuum by high pressure CRDS in the 1.74 µm window / D. Mondelain, A. Campargue, P. Čermák, et al. — DOI 10.1016/j.jqsrt.2017.02.019 // Journal of Quantitative Spectroscopy and Radiative Transfer. — 2017. — Vol. 203. — P. 530-537. |
Abstract: | The very weak absorption continuum of CO2 is studied by Cavity Ring Down Spectroscopy in three 20 cm−1 wide spectral intervals near the centre of the 1.74 µm window (5693–5795 cm−1). For each spectral interval, a set of room temperature spectra is recorded at pressures between 0 and 10 bar thanks to a high pressure CRDS spectrometer. The absorption continuum is retrieved after subtraction of the contributions due to Rayleigh scattering and to local lines of CO2 and water (present as an impurity in the sample) from the measured extinction. Due to some deficiencies of the CO2 HITRAN2012 line list, a composite line list had to be built on the basis of the Ames calculated line list with line positions adjusted according to the Carbon Dioxide Spectroscopic Databank and self-broadening and pressure shift coefficients calculated with the Complex Robert Bonamy method. The local line contribution of the CO2 monomer is calculated using this list and a Voigt profile truncated at ±25 cm−1 from the line centre. Line mixing effects were taken into account through the use of the impact and Energy Corrected Sudden approximations. The density dependence of the retrieved continuum absorption was found to be purely quadratic in the low frequency interval below 5710 cm−1 but a small significant linear contribution was required to reproduce the observations above this value. This linear increase is tentatively attributed to the foreign-continuum of water vapor present in CO2 sample with a relative concentration of some tens ppm. The retrieved binary coefficient is observed to vary smoothly with the wavenumber with a minimum value of 6×10−10 cm−1 amagat−2. By gathering the present data with the results reported in Kassi et al. J Quant Spectrosc Radiat Transf 2015;167:97, a recommended set of binary coefficients is provided for the 5700–5950 cm−1 region. © 2017 Elsevier Ltd |
Keywords: | CARBON DIOXIDE CO2 CONTINUUM TRANSPARENCY WINDOWS VENUS ABSORPTION SPECTROSCOPY LIGHT MEASUREMENT SPECTROMETERS SPECTROSCOPIC ANALYSIS WATER ABSORPTION WATER VAPOR ABSORPTION CONTINUUM CAVITY RING DOWN SPECTROSCOPIES CONTINUUM ENERGY CORRECTED SUDDEN APPROXIMATION RELATIVE CONCENTRATION ROBERT-BONAMY METHODS TEMPERATURE SPECTRA VENUS CARBON DIOXIDE ABSORPTION CARBON DIOXIDE HIGH PRESSURE RAYLEIGH NUMBER VENUS WATER VAPOR |
URI: | http://elar.urfu.ru/handle/10995/102745 |
Access: | info:eu-repo/semantics/openAccess |
SCOPUS ID: | 85014598889 |
WOS ID: | 000414107400045 |
PURE ID: | 2be06eb5-dc3c-4594-a6d4-8bbedc8bcbf1 2210529 |
ISSN: | 224073 |
DOI: | 10.1016/j.jqsrt.2017.02.019 |
Appears in Collections: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2-s2.0-85014598889.pdf | 1,83 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.