Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/94230
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorAsanova, S. M.en
dc.contributor.authorAhyoev, J. S.en
dc.contributor.authorAskarbek, N.en
dc.contributor.authorSuerkulov, S. M.en
dc.contributor.authorAsanova, D. U.en
dc.contributor.authorSafaraliev, M. K.en
dc.date.accessioned2020-12-18T06:31:47Z-
dc.date.available2020-12-18T06:31:47Z-
dc.date.issued2020-
dc.identifier.citationMethod for designing drop-of-wire recognition systems on sections of undistorted two-wire power transmission lines / S. M. Asanova, J. S. Ahyoev, N. Askarbek, S. M. Suerkulov, D. U. Asanova, M. K. Safaraliev. — DOI 10.1088/1757-899X/966/1/012114 // IOP Conference Series: Materials Science and Engineering . — 2020. — Vol. 966. — 12114.en
dc.identifier.issn1757-8981-
dc.identifier.otherhttp://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85097066673m
dc.identifier.urihttp://elar.urfu.ru/handle/10995/94230-
dc.description.abstractIn this work a general statement of the problem of designing distributive electrical systems that recognize breakage of wires on sections of power lines using a multifunctional wire with an isolated residential wire is formulated. The use of overhead wires with the proposed construction of the housing will make it possible to solve many electrical problems very easily and cheaply without the use of expensive equipment. The correspondence table of the information current values of the power supply unit I 0 and of the wire breakdowns on the sections in the two-wire transmission line is obtained by simulation. The proposed method of diagnostics and monitoring of the state of power lines is not expensive and allows the maintenance staff, being at the substation, to detect rapidly and remotely the breakage of wires on the parts of the network and the distance to it, In order to ensure that the repair crew is sent to the exact location of the damage, this will improve the reliability of the electrical supply to consumers. This is achieved by the fact that the information wire has an independent power supply and thus allows for control of the network at any time. © Published under licence by IOP Publishing Ltd.en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherIOP Publishing Ltden
dc.relation.ispartof15th International Conference on Industrial Manufacturing and Metallurgy, ICIMM 2020en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.sourceIOP Conference Series: Materials Science and Engineeringen
dc.titleMethod for designing drop-of-wire recognition systems on sections of undistorted two-wire power transmission linesen
dc.typeConference Paperen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.typeinfo:eu-repo/semantics/conferenceObjecten
dc.conference.name15th International Conference on Industrial Manufacturing and Metallurgy, ICIMM 2020en
dc.conference.date18.06.2020-19.06.2020-
dc.identifier.rsi85097066673
dc.identifier.doi10.1088/1757-899X/966/1/012114-
local.volume966-
local.description.order12114-
local.identifier.eid2-s2.0-85097066673-
Располагается в коллекциях:Междисциплинарные конференции, семинары, сборники

Файлы этого ресурса:
Файл Описание РазмерФормат 
966_1_012114.pdf333,26 kBAdobe PDFПросмотреть/Открыть