Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/92707
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorVasilyev, V. S.en
dc.contributor.authorBorisov, V. I.en
dc.contributor.authorSyskov, A. M.en
dc.contributor.authorKublanov, V. S.en
dc.date.accessioned2020-10-20T16:36:53Z-
dc.date.available2020-10-20T16:36:53Z-
dc.date.issued2019-
dc.identifier.citationVasilyev V. S. Case study of interrelation between brain-computer interface based multimodal metric and heart rate variability / V. S. Vasilyev, V. I. Borisov, A. M. Syskov, V. S. Kublanov. — DOI 10.5220/0007694505320538 // HEALTHINF 2019 - 12th International Conference on Health Informatics, Proceedings; Part of 12th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2019. — 2019. — P. 532-538.en
dc.identifier.isbn9789897583537-
dc.identifier.otherhttps://doi.org/10.5220/0007694505320538pdf
dc.identifier.other1good_DOI
dc.identifier.other6d93e13d-9ac3-43b6-a72f-3779203048c0pure_uuid
dc.identifier.otherhttp://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85064715450m
dc.identifier.urihttp://elar.urfu.ru/handle/10995/92707-
dc.description.abstractThe Brain-Computer Interface (BCI) can be used for evaluation of the state of individuals during everyday routines. As shown in previous works, there is a relationship between the BCI multimodal metric with functional states of human. We have used power of Theta, Alpha, Beta low and Beta high electroencephalography rhythms and head motion data signals for multimodal metric. Heart Rate Variability (HRV) is common medical method for functional state assessment. In this paper the results of interrelation estimation between multimodal metric and HRV are shown. We used Pearson correlation coefficient (PCC) for estimates of interrelation between multimodal metric and HRV. It was found, the best results for estimates of parasympathetic part of the autonomic nervous system and suprasegmental regulation HRV have value of PCC more then critical value for Pearson correlation. © 2019 by SCITEPRESS - Science and Technology Publications, Lda. All rights reserved.en
dc.description.sponsorshipThe work was supported by Act 211 Government of the Russian Federation, contract № 02.A03.21.0006.en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherSciTePressen
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.sourceHEALTHINF 2019 - 12th International Conference on Health Informatics, Proceedings; Part of 12th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2019en
dc.subjectBRAIN-COMPUTER INTERFACEen
dc.subjectHEART RATE VARIABILITYen
dc.subjectMULTIMODAL METRICen
dc.subjectVESTIBULAR APPARATUSen
dc.subjectBIOMEDICAL ENGINEERINGen
dc.subjectCORRELATION METHODSen
dc.subjectELECTROENCEPHALOGRAPHYen
dc.subjectELECTROPHYSIOLOGYen
dc.subjectHEARTen
dc.subjectINTERFACE STATESen
dc.subjectMEDICAL INFORMATICSen
dc.subjectAUTONOMIC NERVOUS SYSTEMen
dc.subjectFUNCTIONAL STATEen
dc.subjectHEART RATE VARIABILITYen
dc.subjectMEDICAL METHODSen
dc.subjectMULTI-MODALen
dc.subjectPEARSON CORRELATIONen
dc.subjectPEARSON CORRELATION COEFFICIENTSen
dc.subjectVESTIBULAR APPARATUSen
dc.subjectBRAIN COMPUTER INTERFACEen
dc.titleCase study of interrelation between brain-computer interface based multimodal metric and heart rate variabilityen
dc.typeConference Paperen
dc.typeinfo:eu-repo/semantics/conferenceObjecten
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.5220/0007694505320538-
dc.identifier.scopus85064715450-
local.affiliationResearch Medical and Biological Engineering Centre of High Technologies, Ural Federal University, Mira Str., 32, Yekaterinburg, 620002, Russian Federation
local.contributor.employeeVasilyev, V.S., Research Medical and Biological Engineering Centre of High Technologies, Ural Federal University, Mira Str., 32, Yekaterinburg, 620002, Russian Federation
local.contributor.employeeBorisov, V.I., Research Medical and Biological Engineering Centre of High Technologies, Ural Federal University, Mira Str., 32, Yekaterinburg, 620002, Russian Federation
local.contributor.employeeSyskov, A.M., Research Medical and Biological Engineering Centre of High Technologies, Ural Federal University, Mira Str., 32, Yekaterinburg, 620002, Russian Federation
local.contributor.employeeKublanov, V.S., Research Medical and Biological Engineering Centre of High Technologies, Ural Federal University, Mira Str., 32, Yekaterinburg, 620002, Russian Federation
local.description.firstpage532-
local.description.lastpage538-
dc.identifier.wos000700363100062-
local.identifier.pure9303950-
local.identifier.eid2-s2.0-85064715450-
local.identifier.wosWOS:000700363100062-
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
10.5220-0007694505320538.pdf531,83 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.