Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://elar.urfu.ru/handle/10995/90630
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor.author | Zdorovets, M. V. | en |
dc.contributor.author | Korolkov, I. V. | en |
dc.contributor.author | Yeszhanov, A. B. | en |
dc.contributor.author | Gorin, Y. G. | en |
dc.date.accessioned | 2020-09-29T09:48:10Z | - |
dc.date.available | 2020-09-29T09:48:10Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Functionalization of PET track-etched membranes by UV-induced graft (co)polymerization for detection of heavy metal ions in water / M. V. Zdorovets, I. V. Korolkov, A. B. Yeszhanov, Y. G. Gorin. — DOI 10.3390/polym11111876 // Polymers. — 2019. — Vol. 11. — Iss. 11. — 1876. | en |
dc.identifier.issn | 2073-4360 | - |
dc.identifier.other | https://www.mdpi.com/2073-4360/11/11/1876/pdf | |
dc.identifier.other | 1 | good_DOI |
dc.identifier.other | f481b88c-d888-4939-9d1f-151fdf10bf3c | pure_uuid |
dc.identifier.other | http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85075549155 | m |
dc.identifier.uri | http://elar.urfu.ru/handle/10995/90630 | - |
dc.description.abstract | Nowadays, water quality monitoring is an essential task since environmental contamination and human exposure to heavy metals increased. Sensors that are able to detect ever lower concentrations of heavy metal ions with greater accuracy and speed are needed to effectively monitor water quality and prevent poisoning. This article shows studies of the modification of flexible track-etched membranes as the basis for the sensor with various polymers and their influence on the accuracy of detection of copper, cadmium, and lead ions in water. We report the UV-induced graft (co)polymerization of acrylic acid (AA) and 4-vinylpyridine (4-VPy) on poly(ethylene terephthalate) track-etched membrane (PET TeMs) and use them after platinum layer sputtering in square wave anodic stripping voltammetry (SW-ASV) for detection of Cu2+, Cd2+, and Pb2+. Optimal conditions leading to functionalization of the surface and retention of the pore structure were found. Modified membranes were characterized by SEM, FTIR, X-ray photoelectron spectroscopy (XPS) and colorimetric analysis. The dependence of the modification method on the sensitivity of the sensor was shown. Membrane modified with polyacrylic acid (PET TeMs-g-PAA), poly(4-vinylpyridine) (PET TeMs-g-P4VPy), and their copolymer (PET TeMs-g-P4VPy/PAA) with average grafting yield of 3% have been found to be sensitive to μg/L concentration of copper, lead, and cadmium ions. Limits of detection (LOD) for sensors based on PET TeMs-g-PAA are 2.22, 1.05, and 2.53 μg/L for Cu2+, Pb2+, and Cd2+, respectively. LODs for sensors based on PET TeMs-g-P4VPy are 5.23 μg/L (Cu2+), 1.78 μg/L (Pb2+), and 3.64 μg/L (Cd2+) μg/L. PET TeMs-g-P4VPy/PAA electrodes are found to be sensitive with LODs of 0.74 μg/L(Cu2+), 1.13 μg/L (Pb2+), and 2.07 μg/L(Cd2+). Thus, it was shown that the modification of membranes by copolymers with carboxylic and amino groups leads to more accurate detection of heavy metal ions, associated with the formation of more stable complexes. © 2019 by the authors. | en |
dc.description.sponsorship | Ministry of Education and Science of the Republic of Kazakhstan | en |
dc.description.sponsorship | Ministry of Education and Science of the Republic of Kazakhstan | en |
dc.description.sponsorship | Funding: The research was funded by the Ministry of Energy of the Republic of Kazakhstan (technological program, #74 on 02.04.2018). | en |
dc.description.sponsorship | Acknowledgments: The research was funded by the Ministry of Energy of the Republic of Kazakhstan (technological program, #74 on 02.04.2018). | en |
dc.format.mimetype | application/pdf | en |
dc.language.iso | en | en |
dc.publisher | MDPI AG | en |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.rights | cc-by | other |
dc.source | Polymers | en |
dc.subject | 4-VINYLPYRIDINE | en |
dc.subject | ACRYLIC ACID | en |
dc.subject | GRAFT POLYMERIZATION | en |
dc.subject | STRIPPING VOLTAMMETRY | en |
dc.subject | TRACK-ETCHED MEMBRANES | en |
dc.subject | CARBOXYLIC ACIDS | en |
dc.subject | CHEMICAL DETECTION | en |
dc.subject | COLORIMETRIC ANALYSIS | en |
dc.subject | COPPER | en |
dc.subject | ETHYLENE | en |
dc.subject | FOURIER TRANSFORM INFRARED SPECTROSCOPY | en |
dc.subject | GRAFTING (CHEMICAL) | en |
dc.subject | HEAVY METALS | en |
dc.subject | MEMBRANES | en |
dc.subject | METAL IONS | en |
dc.subject | POLYETHYLENES | en |
dc.subject | POLYMERIZATION | en |
dc.subject | PORE STRUCTURE | en |
dc.subject | VOLTAMMETRY | en |
dc.subject | WATER QUALITY | en |
dc.subject | X RAY PHOTOELECTRON SPECTROSCOPY | en |
dc.subject | 4-VINYLPYRIDINE | en |
dc.subject | ACRYLIC ACIDS | en |
dc.subject | GRAFT POLYMERIZATION | en |
dc.subject | STRIPPING VOLTAMMETRY | en |
dc.subject | TRACK-ETCHED MEMBRANE | en |
dc.subject | POLYETHYLENE TEREPHTHALATES | en |
dc.title | Functionalization of PET track-etched membranes by UV-induced graft (co)polymerization for detection of heavy metal ions in water | en |
dc.type | Article | en |
dc.type | info:eu-repo/semantics/article | en |
dc.type | info:eu-repo/semantics/publishedVersion | en |
dc.identifier.doi | 10.3390/polym11111876 | - |
dc.identifier.scopus | 85075549155 | - |
local.affiliation | L.N.Gumilyov Eurasian National University, Satpaev str., 5, Nur-Sultan, 010008, Kazakhstan | en |
local.affiliation | The Institute of Nuclear Physics, Ibragimov str., 1, Almaty, 050032, Kazakhstan | en |
local.affiliation | Ural Federal University, Mira str. 19, Ekaterinburg, 620002, Russian Federation | en |
local.contributor.employee | Zdorovets, M.V., L.N.Gumilyov Eurasian National University, Satpaev str., 5, Nur-Sultan, 010008, Kazakhstan, The Institute of Nuclear Physics, Ibragimov str., 1, Almaty, 050032, Kazakhstan, Ural Federal University, Mira str. 19, Ekaterinburg, 620002, Russian Federation | ru |
local.contributor.employee | Korolkov, I.V., L.N.Gumilyov Eurasian National University, Satpaev str., 5, Nur-Sultan, 010008, Kazakhstan, The Institute of Nuclear Physics, Ibragimov str., 1, Almaty, 050032, Kazakhstan | ru |
local.contributor.employee | Yeszhanov, A.B., L.N.Gumilyov Eurasian National University, Satpaev str., 5, Nur-Sultan, 010008, Kazakhstan, The Institute of Nuclear Physics, Ibragimov str., 1, Almaty, 050032, Kazakhstan | ru |
local.contributor.employee | Gorin, Y.G., L.N.Gumilyov Eurasian National University, Satpaev str., 5, Nur-Sultan, 010008, Kazakhstan, The Institute of Nuclear Physics, Ibragimov str., 1, Almaty, 050032, Kazakhstan | ru |
local.issue | 11 | - |
local.volume | 11 | - |
dc.identifier.wos | 000503279200148 | - |
local.identifier.pure | 11331883 | - |
local.description.order | 1876 | - |
local.identifier.eid | 2-s2.0-85075549155 | - |
local.identifier.wos | WOS:000503279200148 | - |
Располагается в коллекциях: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
10.3390-polym11111876.pdf | 3,14 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.