Название: The optimization of radiation protection composition
Авторы: Tashlykov, O. L.
Shcheklein, S. E.
Luk'yanenko, V. Y.
Mikhajlova, A. F.
Russkikh, I. M.
Seleznyov, E. N.
Kozlov, A. V.
Щеклеин, С. Е.
Дата публикации: 2015
Издатель: Obninsk Institute for Nuclear Power Engineering, National Research Nuclear University 'MEPhI'
Библиографическое описание: The optimization of radiation protection composition / O. L. Tashlykov, S. E. Shcheklein, V. Y. Luk'yanenko, A. F. Mikhajlova, et al. . — DOI 10.26583/npe.2015.4.04 // Izvestiya Wysshikh Uchebnykh Zawedeniy, Yadernaya Energetika. — 2015. — Vol. 4. — P. 36-42.
Аннотация: The aim of this work is to develop an algorithm of design of homogeneous composition of the radiation protective materials (RPM) for the optimization of radiation protection. Used for the investigation were the homogeneous radiation protective materials such as Abris, the production technology of which allows to obtain the desired concentration of fillers. The estimation of weakening ability of radiation protective material containing from 20 to 80% of barite, lead, tungsten, was carried out using high-precision calculation codes. To verify the results of calculations the experimental study of protective properties of Abris material with different concentrations of filling was carried out. Five sources of gamma radiation (60Co, 58Co, 198Au, 54Mn, 24Na) with characteristic energies of radiation were produced in IVV-2M research reactor for the experiment. A specially designed experimental installation and measuring device DKS-AT1123 were used. As a result of the research it was obtained the calculated dependency of radiation weakening coefficient for specific for different cases radioactive sources for the various compositions and thicknesses of the RPM. These data become initial for the optimization of radiation protection. Conclusions. 1. The design of RPM of homogeneous composition has considerable potential in the implementation of the radiation protection optimization principle. 2. A comparison oft he results of conducted studies of the gamma radiation dose weakening coefficient with homogeneous radiation protective materials of Abris RZ type depending on the composition and thickness showed that the difference between the experimental data and the values obtained by calculation does not exceed 5%. 3. The technology of production of Abris type homogeneous PRM allows to provide the required protective properties for the specific exposure conditions (composition of radioactive pollution).
Ключевые слова: FREQUENCY RATE OF WEAKENING
HOMOGENOUS RADIATION PROTECTIVE MATERIAL
RADIATION PROTECTION OPTIMIZATION
RESEARCH NUCLEAR REACTOR
URI: http://elar.urfu.ru/handle/10995/90480
Условия доступа: info:eu-repo/semantics/openAccess
Идентификатор РИНЦ: 25805097
Идентификатор SCOPUS: 84989857601
Идентификатор PURE: 1180379
ISSN: 0204-3327
DOI: 10.26583/npe.2015.4.04
Располагается в коллекциях:Научные публикации, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
10.26583-npe.2015.4.04.pdf249,06 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.