dc.date.issued2020-
dc.identifier.citationAref, M. Digital control strategy for SPWM MPPT of PV system with three-phase NPC three-level converter / M. Aref, I. Ahmed, V. Oboskalov. — DOI 10.11591/ijeecs.v19.i2.pp572-585 // Indonesian Journal of Electrical Engineering and Computer Science. — 2020. — Vol. 2. — Iss. 19. — P. 572-585.en
dc.identifier.issn2502-4752-
dc.identifier.otherhttp://ijeecs.iaescore.com/index.php/IJEECS/article/download/18667/13976pdf
dc.identifier.other1good_DOI
dc.identifier.othera0bece2e-3f83-4a56-b647-3f16501f65d6pure_uuid
dc.identifier.otherhttp://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85083713195m
dc.identifier.urihttp://elar.urfu.ru/handle/10995/90419-
dc.description.abstractThis paper is aimed at investigating MPPT of PV system controlled by SPWM which is generated by comparing sinusoidal wave with variable frequency sawtooth wave. Perturb and Observe (P&O) method is used for MPPT control of PV system. NPC three-phase three-level converter with LCL filter is designed to produce output voltage with minimum Total Harmonic Distortion (THD) and high efficiency. The simple and fast method to get MPP of PV system with variable irradiation is digital control where the maximum power point is obtained from look-up table for the values of optimum voltage that achieve the maximum power for each irradiance value is used for digital control signal in microcontroller. The output voltage harmonic of multi-level three-phase inverter is controlled using SPWM control. THD of output voltage of multi-level three-phase inverter is 22% of stand-alone and grid-connected PV system. Small rate LCL filter is used to limit voltage harmonics within medium and low voltage limits (5%). THD output voltage of LCL filter is 4.9% and 3.51% of stand-alone and grid-connected PV system respectively. Copyright © 2020 Institute of Advanced Engineering and Science. All rights reserved.en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherInstitute of Advanced Engineering and Scienceen
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.rightscc-by-ncother
dc.sourceIndonesian Journal of Electrical Engineering and Computer Scienceen
dc.subjectGRIDen
dc.subjectINVERTERen
dc.subjectLCL FILTERen
dc.subjectMULTI-LEVELen
dc.subjectPVen
dc.subjectSTAND-ALONEen
dc.titleDigital control strategy for SPWM MPPT of PV system with three-phase NPC three-level converteren
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.11591/ijeecs.v19.i2.pp572-585-
dc.identifier.scopus85083713195-
local.affiliationUral Power Engineering Institute, Ural Federal University, Russian Federationen
local.affiliationDepartment of Electrical Engineering, Assiut University, Egypten
local.contributor.employeeAref, M., Ural Power Engineering Institute, Ural Federal University, Russian Federation, Department of Electrical Engineering, Assiut University, Egyptru
local.contributor.employeeAhmed, I., Ural Power Engineering Institute, Ural Federal University, Russian Federationru
local.contributor.employeeOboskalov, V., Ural Power Engineering Institute, Ural Federal University, Russian Federationru
local.description.firstpage572-
local.description.lastpage585-
local.issue19-
local.volume2-
local.identifier.pure12650062-
local.identifier.eid2-s2.0-85083713195-
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
10.11591-ijeecs.v19.i2.pp572-585.pdf1,36 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.