Please use this identifier to cite or link to this item:
http://elar.urfu.ru/handle/10995/90198
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Goman, V. | en |
dc.contributor.author | Oshurbekov, S. | en |
dc.contributor.author | Kazakbaev, V. | en |
dc.contributor.author | Prakht, V. | en |
dc.contributor.author | Dmitrievskii, V. | en |
dc.date.accessioned | 2020-09-29T09:46:23Z | - |
dc.date.available | 2020-09-29T09:46:23Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Energy efficiency analysis of fixed-speed pump drives with various types of motors / V. Goman, S. Oshurbekov, V. Kazakbaev, V. Prakht, et al. . — DOI 10.3390/app9245295 // Applied Sciences (Switzerland). — 2019. — Vol. 24. — Iss. 9. — 5295. | en |
dc.identifier.issn | 2076-3417 | - |
dc.identifier.other | https://www.mdpi.com/2076-3417/9/24/5295/pdf | |
dc.identifier.other | 1 | good_DOI |
dc.identifier.other | 8687eeeb-e6f1-449a-99e3-ad9ab10b1966 | pure_uuid |
dc.identifier.other | http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85077382352 | m |
dc.identifier.uri | http://elar.urfu.ru/handle/10995/90198 | - |
dc.description.abstract | The paper presents a comparative analysis of energy consumption by 2.2 kW electric motors of various types and energy efficiency classes in the electric drive of a pump unit with throttle control in a water supply system. Line-start permanent-magnet synchronous motors of the IE4 energy efficiency class and induction motors of the IE4 and IE3 energy efficiency classes of various manufacturers were considered (IE4 and IE3 are labels of energy efficiency classes of electric motors according to IEC 60034-30-1 standard). Energy consumption at a hydraulic load changing under a typical duty cycle was calculated based on the nameplate data of the pump and electric motors. The developed method shows that selecting an electric motor based on the IE energy efficiency class under the IEC 60034-30-1 standard (i.e., based on efficiency at a rated load) may not provide the minimum energy consumption of a variable flow pump unit over a typical duty cycle. In particular, the considered IE4 class line-start permanent-magnet synchronous motors do not provide significant advantages over IE4 class induction motors, and sometimes even over IE3 class induction motors when they are used in variable flow pump units. © 2019 by the authors. | en |
dc.description.sponsorship | Ministry of Education and Science of the Russian Federation, Minobrnauka | en |
dc.description.sponsorship | The research was conducted as part of theme no. 8.9549.2017/8.9. within the frame of the government task of the Ministry of Education and Science of the Russian Federation regarding R&D. | en |
dc.format.mimetype | application/pdf | en |
dc.language.iso | en | en |
dc.publisher | MDPI AG | en |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.rights | cc-by | other |
dc.source | Applied Sciences (Switzerland) | en |
dc.subject | CENTRIFUGAL PUMP | en |
dc.subject | ENERGY EFFICIENCY | en |
dc.subject | ENERGY EFFICIENCY CLASS | en |
dc.subject | INDUCTION MOTOR | en |
dc.subject | LINE-START PERMANENT-MAGNET SYNCHRONOUS MOTOR | en |
dc.subject | THROTTLING CONTROL | en |
dc.title | Energy efficiency analysis of fixed-speed pump drives with various types of motors | en |
dc.type | Article | en |
dc.type | info:eu-repo/semantics/article | en |
dc.type | info:eu-repo/semantics/publishedVersion | en |
dc.identifier.doi | 10.3390/app9245295 | - |
dc.identifier.scopus | 85077382352 | - |
local.affiliation | Nizhniy Tagil Technological Institute, Ural Federal University, Nizhniy Tagil, 622000, Russian Federation | en |
local.affiliation | Department of Electrical Engineering and Electric Technology Systems, Ural Federal University, Yekaterinburg, 620002, Russian Federation | en |
local.contributor.employee | Goman, V., Nizhniy Tagil Technological Institute, Ural Federal University, Nizhniy Tagil, 622000, Russian Federation | ru |
local.contributor.employee | Oshurbekov, S., Department of Electrical Engineering and Electric Technology Systems, Ural Federal University, Yekaterinburg, 620002, Russian Federation | ru |
local.contributor.employee | Kazakbaev, V., Department of Electrical Engineering and Electric Technology Systems, Ural Federal University, Yekaterinburg, 620002, Russian Federation | ru |
local.contributor.employee | Prakht, V., Department of Electrical Engineering and Electric Technology Systems, Ural Federal University, Yekaterinburg, 620002, Russian Federation | ru |
local.contributor.employee | Dmitrievskii, V., Department of Electrical Engineering and Electric Technology Systems, Ural Federal University, Yekaterinburg, 620002, Russian Federation | ru |
local.issue | 9 | - |
local.volume | 24 | - |
dc.identifier.wos | 000518042000030 | - |
local.identifier.pure | 11749740 | - |
local.description.order | 5295 | - |
local.identifier.eid | 2-s2.0-85077382352 | - |
local.identifier.wos | WOS:000518042000030 | - |
Appears in Collections: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
10.3390-app9245295.pdf | 1,31 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.