Название: Novel quantum NMR magnetometer non-contact defectoscopy and monitoring technique for the safe exploitation of gas pipelines
Авторы: Narkhov, E. D.
Sapunov, V. A.
Denisov, A. U.
Savelyev, D. V.
Дата публикации: 2014
Издатель: WITPress
Библиографическое описание: Novel quantum NMR magnetometer non-contact defectoscopy and monitoring technique for the safe exploitation of gas pipelines / E. D. Narkhov, V. A. Sapunov, A. U. Denisov et al. // WIT Transactions on Ecology and the Environment. — 2014. — Vol. 186. — P. 649-658.
Аннотация: Pipeline transportation has already proved to be a high-performance tool of resources transportation for the efficient functioning of modern society. However, an aggressive environment, the modernization of existing pipelines and the building of new pipelines pose a number of problems to be solved for secure exploitation. Such problems include mapping, systems certification, technical inspection and monitoring. Recently much attention has being paid to the effective solution of these problems, with no interference into the functioning of the existing systems (non-contact methods), and the magnetometric technique is one such method. The method presented in this paper is based on the interpretation of the absolute value of the magnetic field of an object, which allows us to carry out measurements more accurately compared to other approaches. This paper presents the preliminary results of the usage of high-precision absolute quantum Overhauser “POS” (proton Overhauser sensor) magnetometers in the oil-and-gas field. The field work conducted in the summer of 2013 showed that this equipment has great potential for safe exploitation of oil-and-gas pipelines. The efficiency of the geophysical equipment for gas pipelines of a large diameter (1400 mm) was also confirmed under actual operating conditions. © 2014 WIT Press.
Ключевые слова: MAGNETOMETER
NON-CONTACT DEFECTOSCOPY
NON-DESTRUCTIVE CONTROL
PIPELINE
GAS PIPELINE
MAGNETIC FIELD
MAGNETOMETER
NUCLEAR MAGNETIC RESONANCE
URI: http://elar.urfu.ru/handle/10995/75789
Условия доступа: info:eu-repo/semantics/openAccess
Конференция/семинар: 5th International Conference on Energy and Sustainability, 2014
Дата конференции/семинара: 16 December 2014 through 18 December 2014
Идентификатор SCOPUS: 84926483896
Идентификатор PURE: 309534
ISSN: 1743-3541
DOI: 10.2495/ESUS140571
Сведения о поддержке: International Journal of Sustainable Development and Planning;WIT Transactions on Ecology and the Environment
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
10.2495-esus140571.pdf1,04 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.