Название: | Developing a modern thermal strengthening technique for regulated fishplate cooling |
Авторы: | Yaroshenko, Y. G. Lipunov, Y. I. Startseva, M. V. Eysmondt, K. Y. Nekrasova, E. V. Trayanov, G. G. |
Дата публикации: | 2014 |
Издатель: | WITPress |
Библиографическое описание: | Developing a modern thermal strengthening technique for regulated fishplate cooling / Y. G. Yaroshenko, Y. I. Lipunov, M. V. Startseva et al. // WIT Transactions on Ecology and the Environment. — 2014. — Vol. 190 VOLUME 1. — P. 491-499. |
Аннотация: | A modern ecologically friendly technique for fishplate (joint bar) thermal strengthening by regulated water cooling is proposed. The proposed technique can successfully replace the conventional one - oil quenching - due to making the cooling process more controlled by obtaining a uniform temperature distribution over fishplate elements with a different mass such as heads and the wet. The oil quenching process is an out of control fire hazardous one and requires controlling the permanent cooling capability, fishplate flushing after the operation. It is necessary to utilize the oil and to have a special ventilation system. As a mineral oil substitute, the usage of polymer media has been investigated. Within the time, the polymer solution needs to be recycled; the high cost of polymer concentrates also plays an important role. Quenching by water spraying is the most ecological and controlled type of thermal strengthening. The technique was validated by a test bench experiment and implemented in the metallurgical industry. The mechanical properties have been obtained to meet the GOST 4133-73 technical requirements. Moreover, the analysis made showed that when the controlled cooling device is fitted into the line existing due to exclusion of the hardening tank and washing machine from the processing flow it is possible to save energy, exclude the expenditures for acquisition, the preparation of oil and washing mixtures as well as for regeneration of the oils used and washing solutions. © 2014 WIT Press. |
Ключевые слова: | ACCELERATED WATER COOLING JOINT BAR (FISHPLATE) SPRAYER SYSTEMS THERMOHARDENING OF ROLLING METAL COOLING POLYMER TEMPERATURE EFFECT |
URI: | http://elar.urfu.ru/handle/10995/75759 |
Условия доступа: | info:eu-repo/semantics/openAccess |
Конференция/семинар: | 1st International Conference on Energy Production and Management in the 21st Century: The Quest for Sustainable Energy |
Дата конференции/семинара: | 23 April 2014 through 25 April 2014 |
Идентификатор SCOPUS: | 84897908519 |
Идентификатор PURE: | 378685 |
ISSN: | 1743-3541 |
DOI: | 10.2495/EQ140471 |
Сведения о поддержке: | International Journal of Safety and Security Engineering;International Journal of Sustainable Development and Planning;WIT Transactions on Ecology and the Environment |
Располагается в коллекциях: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
10.2495-eq140471.pdf | 1,61 MB | Adobe PDF | Просмотреть/Открыть |