Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/75148
Название: ДИАГНОСТИКА УРАВНОВЕШЕННОСТИ ШТАНГОВОЙ ГЛУБИННОЙ НАСОСНОЙ УСТАНОВКИ ПО ВАТТМЕТРОГРАММЕ
Другие названия: Sucker-rod pumping unit balance diagnostics by wattmeter card
Авторы: Zyuzev, A. M.
Bubnov, M. V.
Зюзев, А. М.
Бубнов, М. В.
Дата публикации: 2019
Издатель: Tomsk Polytechnic University, Publishing House
Библиографическое описание: Зюзев А. М. ДИАГНОСТИКА УРАВНОВЕШЕННОСТИ ШТАНГОВОЙ ГЛУБИННОЙ НАСОСНОЙ УСТАНОВКИ ПО ВАТТМЕТРОГРАММЕ / А. М. Зюзев, М. В. Бубнов // Известия Томского политехнического университета. Инжиниринг георесурсов. — 2019. — Т. 330. — №. 4. — С. 178-187.
Аннотация: The relevance of the research is conditioned by widespread use of unregulated sucker-rod pumping units, equipped only with mechani& cal adjustment tools. Application of that type of units results in considerable losses of both electricity and crude oil related to machine ope& rating in non optimal regime. To solve this problem both new and already exploited sucker-rod pumping units are equipped with means of intelligent control and monitoring, which are included within control stations equipped with frequency converter and controller. Imple& mentation of these tools on sucker-rod pumping units control station controller requires the development of appropriate algorithms to ensure autonomous, high performance, cost&effective and reliable function of plant during all life cycle. The main aim of the research is elaboration of the algorithms for determining pumpjack balance, optimal counterbalance position and polished rod dead centres passing moment. Objects of the research are the sucker-rod pumping unit in different operating modes and pumpjack balance, defined by the counter& balance position on the crank. Methods: mathematical analysis tool of differential equations and transfer functions, computer simulation, comparison and analysis of charts and diagrams. Results. The paper considers the existing ways of pumpjack balance detection and their shortcomings. It turns out that wattmetering is the most available and fail&safe sucker-rod pumping unit condition monitoring method which does not require installation of additional external sensors. The authors have developed the sucker-rod pumping unit computer model for investigating principles and load cycles of unit operation. Based on the data obtained by simulations the authors developed the algorithm of pumpjack balance detection, which can work as sucker-rod pumping unit intelligent control station software ensuring easy control, timely service and cost reduction. © 2019 Tomsk Polytechnic University, Publishing House. All rights reserved.
Ключевые слова: BALANCE RATIO
CONTROLLER
COUNTERWEIGHT
DEAD CENTRE
DIAGNOSTICS
FREQUENCY CONVERTER
INDUCTION MOTOR
INTELLIGENT CONTROL STATION
OIL INDUSTRY
PUMPJACK
SUCKER-ROD PUMPING UNIT
WATTMETER CARD
URI: http://elar.urfu.ru/handle/10995/75148
Условия доступа: info:eu-repo/semantics/openAccess
Идентификатор РИНЦ: 38505064
Идентификатор SCOPUS: 85065168768
Идентификатор WOS: 000467367500016
Идентификатор PURE: 9809182
ISSN: 2500-1019
DOI: 10.18799/24131830/2019/4/226
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
10.18799-24131830-2019-4-226.pdf691,88 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.