Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/75110
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorChumarnaya, T.en
dc.contributor.authorTrifanova, M.en
dc.contributor.authorLyubimtseva, T.en
dc.contributor.authorLebedeva, V.en
dc.contributor.authorPoroshin, I.en
dc.contributor.authorTrukshina, M.en
dc.contributor.authorLyasnikova, E.en
dc.contributor.authorSitnikova, M.en
dc.contributor.authorLebedev, D.en
dc.contributor.authorSolovyova, O.en
dc.date.accessioned2019-07-22T06:43:57Z-
dc.date.available2019-07-22T06:43:57Z-
dc.date.issued2017-
dc.identifier.citationImpact of inter-ventricular lead distance on cardiac resynchronization therapy outcomes / T. Chumarnaya, M. Trifanova, T. Lyubimtseva et al. // Computing in Cardiology. — 2017. — Vol. 44. — P. 1-4.en
dc.identifier.issn2325-8861-
dc.identifier.otherhttps://doi.org/10.22489/cinc.2017.290-106pdf
dc.identifier.other1good_DOI
dc.identifier.otherb4a9e278-e7f5-4e51-8a37-519fa692e205pure_uuid
dc.identifier.otherhttp://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85045122578m
dc.identifier.urihttp://elar.urfu.ru/handle/10995/75110-
dc.description.abstractCardiac resynchronization therapy (CRT) has been shown as an essential treatment of patients with heart failure, leading to improvements in symptoms, left ventricular (LV) function, and survival. However, up to 30% of appropriately selected patients remain non-responders to CRT. The aim of our study was to test a hypothesis on the impact of lead positioning in the ventricular walls on CRT response in patients with advanced chronic heart failure with and without pre-operative inter and intra-ventricular myocardial dyssynchrony. We examined 53 guideline-selected CRT candidates. Response to CRT was defined in 6 months after implantation of CRT devices. All patients underwent standard and Doppler echocardiography for assessment of LV function and mechanical dyssynchrony. Individual right ventricular (RV) and LV lead tip position, inter-lead distance, and the horizontal and vertical components were measured on the radiograph images with using an automated custom made software Our results showed that the RLV inter-lead distance is an essential parameter correlated with the CRT outcomes. A logistic model comprising the RLV inter-lead distance with parameters of dyssynchrony demonstrated a high predictive power for odds of CRT success. © 2017 IEEE Computer Society. All rights reserved.en
dc.description.sponsorshipResearch was supported by Act 211 Government of the Russian Federation, agreement № 02.A03.21.0006 and Program of the RAS Presidium #I.33П.en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherIEEE Computer Societyen
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.sourceComputing in Cardiologyen
dc.subjectECHOCARDIOGRAPHYen
dc.subjectHEARTen
dc.subjectOUTAGESen
dc.subjectPATIENT TREATMENTen
dc.subjectCARDIAC RESYNCHRONIZATION THERAPY (CRT)en
dc.subjectCHRONIC HEART FAILURESen
dc.subjectDOPPLER ECHOCARDIOGRAPHYen
dc.subjectLEFT VENTRICULARen
dc.subjectRADIOGRAPH IMAGESen
dc.subjectRIGHT VENTRICULARen
dc.subjectVENTRICULAR WALLSen
dc.subjectVERTICAL COMPONENTen
dc.subjectCARDIAC RESYNCHRONIZATION THERAPYen
dc.titleImpact of inter-ventricular lead distance on cardiac resynchronization therapy outcomesen
dc.typeConference Paperen
dc.typeinfo:eu-repo/semantics/conferenceObjecten
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.conference.name44th Computing in Cardiology Conference, CinC 2017en
dc.conference.date24 September 2017 through 27 September 2017-
dc.identifier.doi10.22489/CinC.2017.290-106-
dc.identifier.scopus85045122578-
local.affiliationInstitute of Immunology and Physiology UB RAS, Pervomayskaya 106, Yekaterinburg, 620049, Russian Federationen
local.affiliationUral Federal University, Ekaterinburg, Russian Federationen
local.affiliationUral State Medical University, Ekaterinburg, Russian Federationen
local.affiliationNational Almazov Medical Research Centre, Saint-Petersburg, Russian Federationen
local.contributor.employeeЧумарная Татьяна Владиславовнаru
local.contributor.employeeСоловьева Ольга Эдуардовнаru
local.description.firstpage1-
local.description.lastpage4-
local.volume44-
dc.identifier.wos000450651100257-
local.identifier.pure7013257-
local.identifier.eid2-s2.0-85045122578-
local.identifier.wosWOS:000450651100257-
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
10.22489-cinc.2017.290-106.pdf321,36 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.