Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/131288
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorPrakht, V.en
dc.contributor.authorDmitrievskii, V.en
dc.contributor.authorKazakbaev, V.en
dc.contributor.authorAnuchin, A.en
dc.date.accessioned2024-04-08T11:06:11Z-
dc.date.available2024-04-08T11:06:11Z-
dc.date.issued2022-
dc.identifier.citationPrakht, V, Dmitrievskii, V, Kazakbaev, V & Anuchin, A 2022, 'Comparative Study of Electrically Excited Conventional and Homopolar Synchronous Motors for the Traction Drive of a Mining Dump Truck Operating in a Wide Speed Range in Field-Weakening Region', Mathematics, Том. 10, № 18, 3364, стр. 3364. https://doi.org/10.3390/math10183364harvard_pure
dc.identifier.citationPrakht, V., Dmitrievskii, V., Kazakbaev, V., & Anuchin, A. (2022). Comparative Study of Electrically Excited Conventional and Homopolar Synchronous Motors for the Traction Drive of a Mining Dump Truck Operating in a Wide Speed Range in Field-Weakening Region. Mathematics, 10(18), 3364. [3364]. https://doi.org/10.3390/math10183364apa_pure
dc.identifier.issn2227-7390-
dc.identifier.otherFinal2
dc.identifier.otherAll Open Access; Gold Open Access3
dc.identifier.otherhttps://www.mdpi.com/2227-7390/10/18/3364/pdf?version=16633211661
dc.identifier.otherhttps://www.mdpi.com/2227-7390/10/18/3364/pdf?version=1663321166pdf
dc.identifier.urihttp://elar.urfu.ru/handle/10995/131288-
dc.description.abstractA synchronous homopolar motor (SHM) has a salient pole passive rotor, an excitation winding located on the stator, and no permanent magnets, which ensures high reliability and makes this type of motor a good alternative to motors traditionally used in traction drives. However, there is no comparison between SHMs and conventional brushed synchronous machines for traction applications in the literature. In this paper, the performances of a wound rotor synchronous machine (WRSM) and SHM are theoretically compared at the operating points of a 370 kW dump mining truck drive traction curve that has a 10:1 constant power range in the field weakening region. The nine-phase motors under comparison have the same outer diameter of the stator lamination. Before comparison, both motor designs are optimized using the Nelder–Mead method to minimize the semiconductor inverter rated current and the operating cycle power loss. The main advantages of the WRSM, which was designed, are reduction in stator length, smaller losses, and smaller inverter. The reduction in the total stator length was by 1.23 times taking into account the winding end parts as well. Losses were reduced by 1.21 times for the same radius of the stator lamination. Finally, the cost of power modules of the inverter was decreased by 1.4 times. SHM is more reliable since its rotor does not have an excitation winding and a diode rectifier, as in a WRSM with a brushless exciter. In addition, SHM provides lower consumption of copper, which reduces the total mass and cost of active materials. This article also introduces a new term, “inverter utilization factor”, which can be useful, more informative than motor power factor, when comparing traction drives with different types of motors. © 2022 by the authors.en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherMDPIen
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.rightscc-byother
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/unpaywall
dc.sourceMathematics2
dc.sourceMathematicsen
dc.subjectCONSTANT POWER SPEED RANGEen
dc.subjectDC EXCITED SYNCHRONOUS MOTORSen
dc.subjectMINING DUMP TRUCKen
dc.subjectNELDER–MEAD METHODen
dc.subjectOPTIMAL DESIGNINGen
dc.subjectSYNCHRONOUS HOMOPOLAR MOTORen
dc.subjectTRACTION DRIVEen
dc.subjectWOUND ROTOR SYNCHRONOUS MOTORen
dc.titleComparative Study of Electrically Excited Conventional and Homopolar Synchronous Motors for the Traction Drive of a Mining Dump Truck Operating in a Wide Speed Range in Field-Weakening Regionen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.3390/math10183364-
dc.identifier.scopus85138609420-
local.contributor.employeePrakht V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federationen
local.contributor.employeeDmitrievskii V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federationen
local.contributor.employeeKazakbaev V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federationen
local.contributor.employeeAnuchin A., Department of Electric Drives, Moscow Power Engineering Institute, Moscow, 111250, Russian Federationen
local.issue18-
local.volume10-
dc.identifier.wos000857662500001-
local.contributor.departmentDepartment of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federationen
local.contributor.departmentDepartment of Electric Drives, Moscow Power Engineering Institute, Moscow, 111250, Russian Federationen
local.identifier.pure30944707-
local.identifier.puref2194a5c-6342-4c67-8028-65d98e8eb7bduuid
local.description.order3364-
local.identifier.eid2-s2.0-85138609420-
local.identifier.wosWOS:000857662500001-
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85138609420.pdf3,63 MBAdobe PDFПросмотреть/Открыть


Лицензия на ресурс: Лицензия Creative Commons Creative Commons