Название: | Single-tuned passive filter (STPF) for mitigating harmonics in a 3-phase power system |
Авторы: | Ishaya, M. M. Adegboye, O. R. Agyekum, E. B. Elnaggar, M. F. Alrashed, M. M. Kamel, S. |
Дата публикации: | 2023 |
Издатель: | Nature Research |
Библиографическое описание: | Ishaya, M, Adegboye, O, Agyekum, E, Elnaggar, M, Alrashed, M & Kamel, S 2023, 'Single-tuned passive filter (STPF) for mitigating harmonics in a 3-phase power system', Scientific Reports, Том. 13, № 1, 20754. https://doi.org/10.1038/s41598-023-47614-7 Ishaya, M., Adegboye, O., Agyekum, E., Elnaggar, M., Alrashed, M., & Kamel, S. (2023). Single-tuned passive filter (STPF) for mitigating harmonics in a 3-phase power system. Scientific Reports, 13(1), [20754]. https://doi.org/10.1038/s41598-023-47614-7 |
Аннотация: | Numerous integrals of the fundamental frequency are known as harmonics and can be found in power systems or electrical circuitry systems. Non-linear loads occasionally drain current or contains a varying impedance with each period of the AC voltage are often responsible for power system harmonics. This can result in system overheating, system losses, and equipment or system damage. In order to achieve the IEEE 519 power quality standard, filters are routinely employed to lower harmonic levels. In this work, we designed a single tuned passive filter (STPF) to minimize harmonics of sequence 5th, 7th, 11th, 13th, 17th, and 19th in a three (3) phase power system. The measurements were taken at the point of common coupling. To test the filter performance, the system and STPF were designed in MATLAB/Simulink, and the simulated results produced without and with STPF were compared. The THDI was reduced from 14.93% down to 4.87% when STPF was connected which is within the IEEE 519-2022 standard; proving that the STPF was effective in decreasing the harmonics to the desired level. © 2023, The Author(s). |
Ключевые слова: | ADULT ARTICLE CONTROLLED STUDY DATA ANALYSIS SOFTWARE DRAIN ELECTRIC POTENTIAL FILTER HEATING IMPEDANCE NORMAL HUMAN SIMULATION |
URI: | http://elar.urfu.ru/handle/10995/130988 |
Условия доступа: | info:eu-repo/semantics/openAccess cc-by |
Текст лицензии: | https://creativecommons.org/licenses/by/4.0/ |
Идентификатор SCOPUS: | 85177745537 |
Идентификатор WOS: | 001117544000048 |
Идентификатор PURE: | 49309021 |
ISSN: | 2045-2322 |
DOI: | 10.1038/s41598-023-47614-7 |
Сведения о поддержке: | Prince Sattam bin Abdulaziz University, PSAU: PSAU/2023/R/1445 This study is supported via funding from prince Sattam bin Abdulaziz University Project number (PSAU/2023/R/1445). |