Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/130629
Название: A promising alternative: examining TVS tellurite glass for gamma radiation shielding applications
Авторы: Uosif, M. A. M.
Issa, S. A. M.
Ene, A.
Mostafa, A. M. A.
Atta, A.
Badawi, A.
El, Agammy, E. F.
Zakaly, H. M. H.
Дата публикации: 2023
Издатель: Frontiers Media SA
Библиографическое описание: Uosif, M, Issa, S, Ene, A, Mostafa, A, Atta, A, Badawi, A, El Agammy, E & Zakaly, H 2023, 'A promising alternative: examining TVS tellurite glass for gamma radiation shielding applications', Frontiers in Materials, Том. 10, 1210524. https://doi.org/10.3389/fmats.2023.1210524
Uosif, M., Issa, S., Ene, A., Mostafa, A., Atta, A., Badawi, A., El Agammy, E., & Zakaly, H. (2023). A promising alternative: examining TVS tellurite glass for gamma radiation shielding applications. Frontiers in Materials, 10, [1210524]. https://doi.org/10.3389/fmats.2023.1210524
Аннотация: Radiation shielding is crucial in many types of medical, industrial, and nuclear facilities due to the widespread usage of radioactive isotopes. In this research, we examine the impact of tellurite 65TeO2–(35-x)V2O5-xSm2O3 glasses, where x ranges from 0.1 to 5 mol%, for its nuclear security and radiation shielding versus gamma attenuation capabilities. For gamma, the effect that the systematic replacement of Sm2O3 with V2O5 has on the shielding qualities was dissected in great depth. In addition, comparative research was carried out using the most recent borate glasses and the typical shielding materials considered the industry standard. In this study, we utilized the FLUKA algorithm and the FLAIR graphical interface to calculate the attenuation coefficients of glass compositions in the 65TeO2–(35-x)V2O5-xSm2O3system. The gamma energies of 0.356, 0.662, 1.332, and 2.614 MeV, commonly used in gamma shielding investigations, were selected as the radiation source. A comparison between the simulation results by FLUKA and theoretical calculations for mass attenuation coefficients demonstrated excellent agreement, confirming the reliability and accuracy of the FLUKA simulation method. The findings of the current research point to the fact that the TVS5 sample has the highest GMAC and lowest GHVL and GMFP, among other glasses. This points to the possibility that the TVS5 sample might be used in radiation shielding activities, which would result in increased nuclear safety. Copyright © 2023 Uosif, Issa, Ene, Mostafa, Atta, Badawi, El Agammy and Zakaly.
Ключевые слова: FLUKA
GAMMA RADIATION
GAMMA RADIATION
SM2O3
SM2O3
TELLURITE GLASS
TELLURITE GLASS
GLASS
RADIATION SHIELDING
SAMARIUM COMPOUNDS
TELLURIUM COMPOUNDS
VANADIUM PENTOXIDE
FLUKA
GAMMA ATTENUATION
INDUSTRIAL FACILITIES
MEDICAL FACILITY
NUCLEAR FACILITIES
NUCLEAR RADIATIONS
NUCLEAR SECURITY
SHIELDING APPLICATIONS
TELLURITE GLASS
GAMMA RAYS
URI: http://elar.urfu.ru/handle/10995/130629
Условия доступа: info:eu-repo/semantics/openAccess
cc-by
Текст лицензии: https://creativecommons.org/licenses/by/4.0/
Идентификатор SCOPUS: 85164302850
Идентификатор WOS: 001020287100001
Идентификатор PURE: 41600938
ISSN: 2296-8016
DOI: 10.3389/fmats.2023.1210524
Сведения о поддержке: DSR2022-RG-0127
This work was funded by the Dean of scientific Research at Jouf University under Grant Number (DSR2022-RG-0127).
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85164302850.pdf1,95 MBAdobe PDFПросмотреть/Открыть


Лицензия на ресурс: Лицензия Creative Commons Creative Commons