Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/130331
Название: Experimental investigation of multilayer brickwork with regard to layer diversity in thermal conductivity and combined action
Авторы: Mekhtiyev, A. D.
Kozhas, A. K.
Fomin, N. I.
Narkevich, M. Y.
Дата публикации: 2023
Издатель: American Institute of Physics Inc.
Библиографическое описание: Mekhtiyev, AD, Kozhas, AК, Fomin, NI & Narkevich, MY 2023, Experimental investigation of multilayer brickwork with regard to layer diversity in thermal conductivity and combined action. в L Boswell, V Alekhin & A Nazarov (ред.), VII International Conference “Safety Problems of Civil Engineering Critical Infrastructures” (SPCECI2021): Conference Proceeding. Том. 2701, 020014, AIP Conference Proceedings, № 1, Том. 2701, American Institute of Physics Inc. https://doi.org/10.1063/5.0122093
Mekhtiyev, A. D., Kozhas, A. К., Fomin, N. I., & Narkevich, M. Y. (2023). Experimental investigation of multilayer brickwork with regard to layer diversity in thermal conductivity and combined action. в L. Boswell, V. Alekhin, & A. Nazarov (Ред.), VII International Conference “Safety Problems of Civil Engineering Critical Infrastructures” (SPCECI2021): Conference Proceeding (Том 2701). [020014] (AIP Conference Proceedings; Том 2701, № 1). American Institute of Physics Inc.. https://doi.org/10.1063/5.0122093
Аннотация: Insufficient experience in the design of multi-layer brick walls as well as the lack of an adequate number of experimental studies can result in the disfunction of the normal operation of a building, such as the introduction of defects and damages represented by vertical cracks in a building. The investigation is concerned with an apartment building made up of eight 5-storeyed interlocked block sections of a broken shape. In exterior walls of the first floor, a layer of expanded clay concrete (layer thickness is 150 mm) is employed as a heat insulator between the main brickwork and the facing brick, the typical floor is made of mineral wool insulation of the PPG-200 brand. Experimental studies confirm that the combined action of a multilayer wall structure such as an internal main bearing wall made of silicate bricks (layer thickness is 380 mm), expanded clay insulation (layer thickness is 150 mm) and ceramic brick facing (layer thickness is 120 mm) is not provided. Thus, the fact of design error is established. © 2023 Author(s).
URI: http://elar.urfu.ru/handle/10995/130331
Условия доступа: info:eu-repo/semantics/openAccess
Конференция/семинар: 7th International Conference on Safety Problems of Civil Engineering Critical Infrastructures, SPCECI 2021
Дата конференции/семинара: 27 May 2021 through 28 May 2021
Идентификатор SCOPUS: 85151326831
Идентификатор PURE: 37136694
ISSN: 0094-243X
ISBN: 9780735444157
DOI: 10.1063/5.0122093
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85151326831.pdf747,79 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.