Название: | Experimental investigation of multilayer brickwork with regard to layer diversity in thermal conductivity and combined action |
Авторы: | Mekhtiyev, A. D. Kozhas, A. K. Fomin, N. I. Narkevich, M. Y. |
Дата публикации: | 2023 |
Издатель: | American Institute of Physics Inc. |
Библиографическое описание: | Mekhtiyev, AD, Kozhas, AК, Fomin, NI & Narkevich, MY 2023, Experimental investigation of multilayer brickwork with regard to layer diversity in thermal conductivity and combined action. в L Boswell, V Alekhin & A Nazarov (ред.), VII International Conference “Safety Problems of Civil Engineering Critical Infrastructures” (SPCECI2021): Conference Proceeding. Том. 2701, 020014, AIP Conference Proceedings, № 1, Том. 2701, American Institute of Physics Inc. https://doi.org/10.1063/5.0122093 Mekhtiyev, A. D., Kozhas, A. К., Fomin, N. I., & Narkevich, M. Y. (2023). Experimental investigation of multilayer brickwork with regard to layer diversity in thermal conductivity and combined action. в L. Boswell, V. Alekhin, & A. Nazarov (Ред.), VII International Conference “Safety Problems of Civil Engineering Critical Infrastructures” (SPCECI2021): Conference Proceeding (Том 2701). [020014] (AIP Conference Proceedings; Том 2701, № 1). American Institute of Physics Inc.. https://doi.org/10.1063/5.0122093 |
Аннотация: | Insufficient experience in the design of multi-layer brick walls as well as the lack of an adequate number of experimental studies can result in the disfunction of the normal operation of a building, such as the introduction of defects and damages represented by vertical cracks in a building. The investigation is concerned with an apartment building made up of eight 5-storeyed interlocked block sections of a broken shape. In exterior walls of the first floor, a layer of expanded clay concrete (layer thickness is 150 mm) is employed as a heat insulator between the main brickwork and the facing brick, the typical floor is made of mineral wool insulation of the PPG-200 brand. Experimental studies confirm that the combined action of a multilayer wall structure such as an internal main bearing wall made of silicate bricks (layer thickness is 380 mm), expanded clay insulation (layer thickness is 150 mm) and ceramic brick facing (layer thickness is 120 mm) is not provided. Thus, the fact of design error is established. © 2023 Author(s). |
URI: | http://elar.urfu.ru/handle/10995/130331 |
Условия доступа: | info:eu-repo/semantics/openAccess |
Конференция/семинар: | 7th International Conference on Safety Problems of Civil Engineering Critical Infrastructures, SPCECI 2021 |
Дата конференции/семинара: | 27 May 2021 through 28 May 2021 |
Идентификатор SCOPUS: | 85151326831 |
Идентификатор PURE: | 37136694 |
ISSN: | 0094-243X |
ISBN: | 9780735444157 |
DOI: | 10.1063/5.0122093 |
Располагается в коллекциях: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
2-s2.0-85151326831.pdf | 747,79 kB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.