Название: | Experimental Study on Performance Enhancement of a Photovoltaic Module Using a Combination of Phase Change Material and Aluminum Fins—Exergy, Energy and Economic (3e) Analysis |
Авторы: | Agyekum, E. B. Praveenkumar, S. Alwan, N. T. Velkin, V. I. Adebayo, T. S. |
Дата публикации: | 2021 |
Издатель: | MDPI MDPI AG |
Библиографическое описание: | Experimental Study on Performance Enhancement of a Photovoltaic Module Using a Combination of Phase Change Material and Aluminum Fins—Exergy, Energy and Economic (3e) Analysis / E. B. Agyekum, S. Praveenkumar, N. T. Alwan et al. // Inventions. — 2021. — Vol. 6. — Iss. 4. — 69. |
Аннотация: | The electrical performance of a photovoltaic (PV) module is hugely affected by its tempera-ture. This study proposed a passive cooling mechanism for the cooling of a PV panel. The proposed cooling system is made up of a combination of aluminum fins and paraffin wax integrated at the PV panel’s rear side. The average temperature for the cooled panel for the entire period of the experiment is 36.62◦C against 48.75◦C for the referenced PV module. This represents an average reduction of 12.13◦C for the cooled panel. The average power for the cooled panel is 12.19 W against 10.95 W for the referenced module which is 11.33% improvement. The electrical efficiencies for the cooled panel and the referenced modules are 14.30% and 13.60%, respectively, representing an improvement of 5.15% in the electrical efficiency. The cooled solar PV module had an average exergy efficiency of 7.99% compared to 5.61% for the referenced module. In terms of the economics, the results from the computations show that LCOE of the cooled panel can range between 0.198 and 0.603 $/kWh, while that of the referenced module ranges from 0.221–0.671 $/kWh depending on the number of days it operates. © 2021 by the authors. Licensee MDPI, Basel, Switzerland. |
Ключевые слова: | EXERGY EFFICIENCY LEVELIZED COST OF ENERGY PARAFFIN WAX PASSIVE COOLING PHOTOVOLTAIC PANEL COOLING |
URI: | http://elar.urfu.ru/handle/10995/111888 |
Условия доступа: | info:eu-repo/semantics/openAccess |
Идентификатор SCOPUS: | 85118141416 |
Идентификатор WOS: | 000742451800001 |
Идентификатор PURE: | 28889262 |
ISSN: | 2411-5134 |
DOI: | 10.3390/inventions6040069 |