Название: | Impact of Eye and Breast Shielding on Organ Doses During Cervical Spine Radiography: Design and Validation of MIRD Computational Phantom |
Авторы: | Elshami, W. Tekin, H. O. Issa, S. A. M. Abuzaid, M. M. Zakaly, H. M. H. Issa, B. Ene, A. |
Дата публикации: | 2021 |
Издатель: | Frontiers Media S.A. Frontiers Media SA |
Библиографическое описание: | Impact of Eye and Breast Shielding on Organ Doses During Cervical Spine Radiography: Design and Validation of MIRD Computational Phantom / W. Elshami, H. O. Tekin, S. A. M. Issa et al. // Frontiers in Public Health. — 2021. — Vol. 9. — 751577. |
Аннотация: | Purpose: The study aimed to design and validate computational phantoms (MIRD) using the MCNPX code to assess the impact of shielding on organ doses. Method: To validate the optimized phantom, the obtained results were compared with experimental results. The validation of the optimized MIRD phantom was provided by using the results of a previous anthropomorphic phantom study. MIRD phantom was designed by considering the parameters used in the anthropomorphic phantom study. A test simulation was performed to compare the dose reduction percentages (%) between the experimental anthropomorphic phantom study and the MCNPX-MIRD phantom. The simulation was performed twice, with and without shielding materials, using the same number and locations of the detector. Results: The absorbed dose amounts were directly extracted from the required organ and tissue cell parts of output files. Dose reduction percentages between the simulation with shielding and simulation without shielding were compared. The highest dose reduction was noted in the thymus (95%) and breasts (88%). The obtained dose reduction percentages between the anthropomorphic phantom study and the MCNPX-MIRD phantom were highly consistent and correlated values with experimental anthropomorphic data. Both methods showed Relative Difference (%) ranges between 0.88 and 2.22. Moreover, the MCNPX-MIRD optimized phantom provides detailed dose analysis for target and non-target organs and can be used to assess the efficiency of shielding in radiological examination. Conclusion: Shielding breasts and eyes during cervical radiography reduced the radiation dose to many organs. The decision to not shield patients should be based on research evidence as this approach does not apply to all cases. Copyright © 2021 Elshami, Tekin, Issa, Abuzaid, Zakaly, Issa and Ene. |
Ключевые слова: | DOSE REDUCTION MCNPX MONTE CARLO METHOD RADIATION PROTECTION SHIELDING CERVICAL VERTEBRA DIAGNOSTIC IMAGING HUMAN RADIATION DOSE RADIATION PROTECTION RADIOGRAPHY X-RAY COMPUTED TOMOGRAPHY CERVICAL VERTEBRAE HUMANS RADIATION DOSAGE RADIATION PROTECTION RADIOGRAPHY TOMOGRAPHY, X-RAY COMPUTED |
URI: | http://elar.urfu.ru/handle/10995/111832 |
Условия доступа: | info:eu-repo/semantics/openAccess |
Идентификатор РИНЦ: | 47523579 |
Идентификатор SCOPUS: | 85118728059 |
Идентификатор WOS: | 000716363300001 |
Идентификатор PURE: | 28949431 |
ISSN: | 2296-2565 |
DOI: | 10.3389/fpubh.2021.751577 |
Сведения о поддержке: | The APC was supported by Dunarea de Jos University of Galati, Romania. |
Располагается в коллекциях: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
2-s2.0-85118728059.pdf | 1,59 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.