Название: Analysis of the Payback Period of a Modernized Pump Unit with Induction Electric Motors of Advanced Energy Efficiency Classes
Авторы: Goman, V. V.
Prakht, V. A.
Kazakbaev, V. M.
Dmitrievskii, V. A.
Valeev, E. A.
Paramonov, A. S.
Дата публикации: 2021
Издатель: National Technical University "Kharkiv Polytechnic Institute"
National Technical University Kharkiv Polytechnic Institute
Библиографическое описание: Analysis of the Payback Period of a Modernized Pump Unit with Induction Electric Motors of Advanced Energy Efficiency Classes / V. V. Goman, V. A. Prakht, V. M. Kazakbaev et al. // Electrical Engineering and Electromechanics. — 2021. — Vol. — Iss. 1. — P. 15-19.
Аннотация: Aim. The comparative analysis of energy consumption, electricity costs during lifetime cycle and payback period of a pump unit with 90 kW 2-pole induction motors, belonging to various energy efficiency classes, feeding directly from power grid. Methods. The examined operating modes aligned with a typical operating cycle of a pump unit with approximately constant flow rate of 75-110 % of the rated flow. The calculations were based on the pump and induction motors nameplate data, which, in their turn, were based on the manufacturers’ experimental data. Results. The calculations of energy consumption, electricity costs and payback periods of a pump unit with 90 kW 2-pole induction motors, feeding directly from power grid have been performed in the article. The application of induction motors belonging to IE2, IE3 and IE4 energy efficiency classes has been discussed. Practical value. It has been demonstrated, than in case of replacement of an induction motor of energy efficiency class IE2 due to planned retrofit, payback period for an IE4 induction motor is 2.18 years, energy savings within a calculated 20-year operating period are 268MW·h, which makes €41110 in money terms. under the same conditions, the replacement of an induction motor of energy efficiency class IE2 with an induction motor of energy efficiency class IE3 will allow to save 88 MW·h within a calculated operating period, which, expressed in monetary terms, is €13500 and the payback period is 5.11 years. Thus, the article proves that despite a higher initial price, the choice of an induction motor of energy efficiency class IE4 tends to be more economically advantageous. © 2021, National Technical University "Kharkiv Polytechnic Institute". All rights reserved.
Ключевые слова: CENTRIFUGAL PUMP
ENERGY EFFICIENCY
ENERGY EFFICIENCY CLASS
ENERGY SAVING
INDUCTION MOTOR
LIFETIME CYCLE
PAYBACK PERIOD
THROTTLING CONTROL
URI: http://elar.urfu.ru/handle/10995/111778
Условия доступа: info:eu-repo/semantics/openAccess
Идентификатор РИНЦ: 47537600
Идентификатор SCOPUS: 85120782417
Идентификатор WOS: 000621797800003
Идентификатор PURE: 21045700
ISSN: 2074-272X
DOI: 10.20998/2074-272X.2021.1.03
Сведения о поддержке: Acknowledgment. The work was partially supported by the Ministry of Science and Higher Education of the Russian Federation (through the basic part of the government mandate, Project No. FEUZ-2020-0060).
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85120782417.pdf493,92 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.