dc.date.issued2020-
dc.identifier.citationComparative study of induction motors of IE2, IE3 and IE4 efficiency classes in pump applications taking into account CO2 emission intensity / V. Goman, V. Prakht, V. Kazakbaev, et al. — DOI 10.3390/app10238536 // Applied Sciences (Switzerland). — 2020. — Vol. 10. — Iss. 23. — P. 1-10. — 8536.en
dc.identifier.issn20763417-
dc.identifier.otherFinal2
dc.identifier.otherAll Open Access, Gold3
dc.identifier.otherhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85096976700&doi=10.3390%2fapp10238536&partnerID=40&md5=05919a611ae149372d07fb69c214d08e
dc.identifier.otherhttps://www.mdpi.com/2076-3417/10/23/8536/pdfm
dc.identifier.urihttp://elar.urfu.ru/handle/10995/103268-
dc.description.abstractThe high energy intensity of the modern industry and the threat of climate change determine the high urgency of increasing the energy efficiency of electric motors. In this paper, energy consumption, energy costs, payback periods, and CO2 emissions of 75 kW, 4 pole induction motors with direct grid supply in a fixed-speed pump unit are evaluated. Motors of the IE2, IE3, and IE4 efficiency classes according to IEC 60034-30-1 standard are compared in terms of life-time energy savings, payback period, and CO2 emissions. To carry out the analysis, polynomial interpolation of the data from the available manufacturer datasheets of the motors is used. It concluded that even though the initial investment cost of the IE4-motor is higher than that of IE3-motor, the IE4-motor is more profitable if more than 3 years of operation are considered and also provides significant reductions of CO2 emissions. The paper presents a calculation method of the aforementioned indicators which can be useful for companies, researchers, and engineers for quick assessment and selection of technical solutions. © 2020 by the authors. Licensee MDPI, Basel, Switzerland.en
dc.description.sponsorshipThe work was partially supported by the Ministry of Science and Higher Education of the Russian Federation (through the basic part of the government mandate, Project No. FEUZ-2020-0060).en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherMDPI AGen
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.sourceAppl. Sci.2
dc.sourceApplied Sciences (Switzerland)en
dc.subjectCARBON DIOXIDE EMISSIONSen
dc.subjectCENTRIFUGAL PUMPen
dc.subjectCLIMATE CHANGE MITIGATIONen
dc.subjectCOST SAVINGSen
dc.subjectENERGY CONVERSIONen
dc.subjectENERGY EFFICIENCYen
dc.subjectENERGY EFFICIENCY CLASSen
dc.subjectENERGY POLICIES AND REGULATIONen
dc.subjectENVIRONMENTAL IMPACT ASSESSMENTen
dc.subjectINDUCTION MOTORen
dc.subjectLIFETIME COSTen
dc.subjectLOW-CARBON DEVELOPMENTen
dc.subjectSUSTAINABLE UTILIZATION OF RESOURCESen
dc.subjectTHROTTLING CONTROLen
dc.titleComparative study of induction motors of IE2, IE3 and IE4 efficiency classes in pump applications taking into account CO2 emission intensityen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.3390/app10238536-
dc.identifier.scopus85096976700-
local.contributor.employeeGoman, V., Nizhniy Tagil Technological Institute, Ural Federal University, Nizhniy Tagil, 622000, Russian Federation
local.contributor.employeePrakht, V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation
local.contributor.employeeKazakbaev, V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation
local.contributor.employeeDmitrievskii, V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation
local.description.firstpage1-
local.description.lastpage10-
local.issue23-
local.volume10-
dc.identifier.wos000597813800001-
local.contributor.departmentNizhniy Tagil Technological Institute, Ural Federal University, Nizhniy Tagil, 622000, Russian Federation
local.contributor.departmentDepartment of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation
local.identifier.pure6a141e14-d3d3-4f73-9a90-d65b37d6f2a6uuid
local.identifier.pure20214995-
local.description.order8536-
local.identifier.eid2-s2.0-85096976700-
local.identifier.wosWOS:000597813800001-
local.fund.feuzFEUZ-2020-0060-
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85096976700.pdf1,68 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.