Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://elar.urfu.ru/handle/10995/102973
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor.author | Oshurbekov, S. | en |
dc.contributor.author | Kazakbaev, V. | en |
dc.contributor.author | Prakht, V. | en |
dc.contributor.author | Dmitrievskii, V. | en |
dc.contributor.author | Gevorkov, L. | en |
dc.date.accessioned | 2021-08-31T15:06:41Z | - |
dc.date.available | 2021-08-31T15:06:41Z | - |
dc.date.issued | 2020 | - |
dc.identifier.citation | Energy consumption comparison of a single variable-speed pump and a system of two pumps: Variable-speed and fixed-speed / S. Oshurbekov, V. Kazakbaev, V. Prakht, et al. — DOI 10.3390/app10248820 // Applied Sciences (Switzerland). — 2020. — Vol. 10. — Iss. 24. — P. 1-14. — 8820. | en |
dc.identifier.issn | 20763417 | - |
dc.identifier.other | Final | 2 |
dc.identifier.other | All Open Access, Gold | 3 |
dc.identifier.other | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85103860760&doi=10.3390%2fapp10248820&partnerID=40&md5=27b129824e88cd889631f56456860aca | |
dc.identifier.other | https://www.mdpi.com/2076-3417/10/24/8820/pdf | m |
dc.identifier.uri | http://elar.urfu.ru/handle/10995/102973 | - |
dc.description.abstract | The energy efficiency of a multi-pump system consisting of two low-power (0.75 kW) pumps operating in parallel mode and a single-pump mechanism (1.5 kW) is compared in this study. For this purpose, mathematical models, experimental data, and data retrieved from the manuals provided by the pump manufacturers are used. The single-pump system is fed by a single variable speed drive. A multi-pump system running in parallel mode consists of two pumps. One of them is driven by an induction motor connected directly to the electrical grid and equipped with a throttle. Another pump is actuated by an induction motor fed by a variable speed drive. The flowrate of the liquid in the multi-pump is controlled with the help of speed variation and throttling. In the case of the single-pump system the conventional speed control method is applied during the analysis. For both pump system topologies, the daily and annual energy consumption is obtained. As a result of conducted calculations, it was shown that the multi-pump provides 29.8% savings in comparison to the single-pump system in the case of a typical flowrate profile. © 2020 by the authors. Licensee MDPI, Basel, Switzerland. | en |
dc.description.sponsorship | The work was partially supported by the Ministry of Science and Higher Education of the Russian Federation (through the basic part of the government mandate, Project No. FEUZ-2020-0060). | en |
dc.format.mimetype | application/pdf | en |
dc.language.iso | en | en |
dc.publisher | MDPI AG | en |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.source | Appl. Sci. | 2 |
dc.source | Applied Sciences (Switzerland) | en |
dc.subject | CENTRIFUGAL PUMP | en |
dc.subject | ENERGY EFFICIENCY | en |
dc.subject | INDUCTION MOTOR | en |
dc.subject | THROTTLING CONTROL | en |
dc.subject | VARIABLE SPEED CONTROL | en |
dc.title | Energy consumption comparison of a single variable-speed pump and a system of two pumps: Variable-speed and fixed-speed | en |
dc.type | Article | en |
dc.type | info:eu-repo/semantics/article | en |
dc.type | info:eu-repo/semantics/publishedVersion | en |
dc.identifier.doi | 10.3390/app10248820 | - |
dc.identifier.scopus | 85103860760 | - |
local.contributor.employee | Oshurbekov, S., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation | |
local.contributor.employee | Kazakbaev, V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation | |
local.contributor.employee | Prakht, V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation | |
local.contributor.employee | Dmitrievskii, V., Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation | |
local.contributor.employee | Gevorkov, L., Faculty of Electrical Engineering, University of West Bohemia, Pilsen, 301 00, Czech Republic | |
local.description.firstpage | 1 | - |
local.description.lastpage | 14 | - |
local.issue | 24 | - |
local.volume | 10 | - |
dc.identifier.wos | 000602955200001 | - |
local.contributor.department | Department of Electrical Engineering, Ural Federal University, Yekaterinburg, 620002, Russian Federation | |
local.contributor.department | Faculty of Electrical Engineering, University of West Bohemia, Pilsen, 301 00, Czech Republic | |
local.identifier.pure | 20521925 | - |
local.description.order | 8820 | - |
local.identifier.eid | 2-s2.0-85103860760 | - |
local.identifier.wos | WOS:000602955200001 | - |
local.fund.feuz | FEUZ-2020-0060 | - |
Располагается в коллекциях: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
2-s2.0-85103860760.pdf | 2,61 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.