Название: Magnetic actuator based on giant magnetostrictive material Terfenol-D with strain and temperature monitoring using FBG optical sensor
Авторы: García-Miquel, H.
Barrera, D.
Amat, R.
Kurlyandskaya, G. V.
Sales, S.
Дата публикации: 2016
Издатель: Elsevier B.V.
Библиографическое описание: Magnetic actuator based on giant magnetostrictive material Terfenol-D with strain and temperature monitoring using FBG optical sensor / H. García-Miquel, D. Barrera, R. Amat, et al. — DOI 10.1016/j.measurement.2015.11.035 // Measurement: Journal of the International Measurement Confederation. — 2016. — Vol. 80. — P. 201-206.
Аннотация: We have designed a temperature and strain monitoring system for a magnetic actuator based on the giant magnetostrictive material Terfenol-D (Tb0.3 Dy0.7Fe1.92) with Fiber Bragg grating (FBG) sensors. Magneto-elastic properties of Terfenol-D depend on magnetization, stress pre-history, and temperature. In order to simultaneously monitor these effects, we have implemented a system based on a cylindrical Terfenol-D rod monitored with four FBGs that allows making the appropriate compensations on the strain measurement due to temperature drift. We have measured the magnetostriction in the axial and the transverse directions for the Terfenol-D rod with two perpendicular FBGs, and calculated the Poisson ratio. An additional mechanical system for strain amplification has been designed in order to increase sensitivity, by a factor of 4, in the strain measurement with the FBG sensor. © 2015 Elsevier Ltd.
Ключевые слова: FIBER BRAGG GRATING
FIBER OPTIC
MAGNETIC OPTIC ACTUATOR
MAGNETO OPTIC SENSORS
MAGNETOSTRICTION
TERFENOL-D
ACTUATORS
BRAGG GRATINGS
FIBER OPTIC SENSORS
FIBER OPTICS
MAGNETIC ACTUATORS
MAGNETISM
MAGNETOSTRICTION
MAGNETOSTRICTIVE DEVICES
STRAIN MEASUREMENT
FIBER BRAGG GRATING SENSORS
GIANT MAGNETOSTRICTIVE MATERIALS
MAGNETOOPTIC SENSORS
MECHANICAL SYSTEMS
STRAIN AMPLIFICATION
STRAIN MONITORING SYSTEM
TEMPERATURE MONITORING
TERFENOL-D
FIBER BRAGG GRATINGS
URI: http://elar.urfu.ru/handle/10995/102330
Условия доступа: info:eu-repo/semantics/openAccess
Идентификатор SCOPUS: 84949560189
Идентификатор WOS: 000367236000021
Идентификатор PURE: f1f72fc1-692c-4002-9f46-b97249d0092b
605015
ISSN: 2632241
DOI: 10.1016/j.measurement.2015.11.035