Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/101703
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorChusovitin, P.en
dc.contributor.authorPazderin, A.en
dc.date.accessioned2021-08-31T14:59:09Z-
dc.date.available2021-08-31T14:59:09Z-
dc.date.issued2012-
dc.identifier.citationChusovitin P. Power system monitoring using phasor measurements / P. Chusovitin, A. Pazderin. — DOI 10.24084/repqj10.589 // Renewable Energy and Power Quality Journal. — 2012. — Vol. 1. — Iss. 10. — P. 1069-1072. — 589.en
dc.identifier.issn2172038X-
dc.identifier.otherFinal2
dc.identifier.otherAll Open Access, Bronze, Green3
dc.identifier.otherhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85072215773&doi=10.24084%2frepqj10.589&partnerID=40&md5=0f74291cf9912b008af7c2cad53b3a0e
dc.identifier.otherhttps://doi.org/10.24084/repqj10.589m
dc.identifier.urihttp://elar.urfu.ru/handle/10995/101703-
dc.description.abstractThe paper describes investigation of the new opportunities for power system monitoring and control using phasor measurements. Phasor measurements are used for power system model identification in the form of state-space model. Implementing the modal analysis to identified state-space model gives the opportunity to control proximity of the operation point to the feasibility boundary. Also, identified state-space model allows predicting power system transient. All time domain simulations of the research are conducted for two-generator-swing-bus system. Calculations were carried out in Matlab. © 2012, European Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ). All rights reserved.en
dc.format.mimetypeapplication/pdfen
dc.language.isoenen
dc.publisherEuropean Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ)en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.sourceRenewable Energy and Power Qual. J.2
dc.sourceRenewable Energy and Power Quality Journalen
dc.subjectMODAL ANALYSISen
dc.subjectMOESPen
dc.subjectSYSTEM IDENTIFICATIONen
dc.subjectWACSen
dc.subjectWAMSen
dc.titlePower system monitoring using phasor measurementsen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.24084/repqj10.589-
dc.identifier.scopus85072215773-
local.contributor.employeeChusovitin, P., Automated power systems department, Ural Energy Institute, Russian Federation
local.contributor.employeePazderin, A., Automated power systems department, Ural Energy Institute, Russian Federation
local.description.firstpage1069-
local.description.lastpage1072-
local.issue10-
local.volume1-
local.contributor.departmentAutomated power systems department, Ural Energy Institute, Russian Federation
local.identifier.pure21170414-
local.identifier.purea1149f1e-df12-4ba7-977f-896363f2ef7buuid
local.description.order589-
local.identifier.eid2-s2.0-85072215773-
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85072215773.pdf885,42 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.