Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://elar.urfu.ru/handle/10995/101703
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor.author | Chusovitin, P. | en |
dc.contributor.author | Pazderin, A. | en |
dc.date.accessioned | 2021-08-31T14:59:09Z | - |
dc.date.available | 2021-08-31T14:59:09Z | - |
dc.date.issued | 2012 | - |
dc.identifier.citation | Chusovitin P. Power system monitoring using phasor measurements / P. Chusovitin, A. Pazderin. — DOI 10.24084/repqj10.589 // Renewable Energy and Power Quality Journal. — 2012. — Vol. 1. — Iss. 10. — P. 1069-1072. — 589. | en |
dc.identifier.issn | 2172038X | - |
dc.identifier.other | Final | 2 |
dc.identifier.other | All Open Access, Bronze, Green | 3 |
dc.identifier.other | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072215773&doi=10.24084%2frepqj10.589&partnerID=40&md5=0f74291cf9912b008af7c2cad53b3a0e | |
dc.identifier.other | https://doi.org/10.24084/repqj10.589 | m |
dc.identifier.uri | http://elar.urfu.ru/handle/10995/101703 | - |
dc.description.abstract | The paper describes investigation of the new opportunities for power system monitoring and control using phasor measurements. Phasor measurements are used for power system model identification in the form of state-space model. Implementing the modal analysis to identified state-space model gives the opportunity to control proximity of the operation point to the feasibility boundary. Also, identified state-space model allows predicting power system transient. All time domain simulations of the research are conducted for two-generator-swing-bus system. Calculations were carried out in Matlab. © 2012, European Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ). All rights reserved. | en |
dc.format.mimetype | application/pdf | en |
dc.language.iso | en | en |
dc.publisher | European Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ) | en |
dc.rights | info:eu-repo/semantics/openAccess | en |
dc.source | Renewable Energy and Power Qual. J. | 2 |
dc.source | Renewable Energy and Power Quality Journal | en |
dc.subject | MODAL ANALYSIS | en |
dc.subject | MOESP | en |
dc.subject | SYSTEM IDENTIFICATION | en |
dc.subject | WACS | en |
dc.subject | WAMS | en |
dc.title | Power system monitoring using phasor measurements | en |
dc.type | Article | en |
dc.type | info:eu-repo/semantics/article | en |
dc.type | info:eu-repo/semantics/publishedVersion | en |
dc.identifier.doi | 10.24084/repqj10.589 | - |
dc.identifier.scopus | 85072215773 | - |
local.contributor.employee | Chusovitin, P., Automated power systems department, Ural Energy Institute, Russian Federation | |
local.contributor.employee | Pazderin, A., Automated power systems department, Ural Energy Institute, Russian Federation | |
local.description.firstpage | 1069 | - |
local.description.lastpage | 1072 | - |
local.issue | 10 | - |
local.volume | 1 | - |
local.contributor.department | Automated power systems department, Ural Energy Institute, Russian Federation | |
local.identifier.pure | 21170414 | - |
local.identifier.pure | a1149f1e-df12-4ba7-977f-896363f2ef7b | uuid |
local.description.order | 589 | - |
local.identifier.eid | 2-s2.0-85072215773 | - |
Располагается в коллекциях: | Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
2-s2.0-85072215773.pdf | 885,42 kB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.