Please use this identifier to cite or link to this item: http://hdl.handle.net/10995/50265
Title: Проточно-инжекционное определение валина пьезокварцевым сенсором, модифицированным полимером с молекулярными отпечатками
Other Titles: Flow-injection determination of valine with piezoelectric sensors, modified by molecular imprinted polymers
Authors: Зяблов, А. Н.
Говорухин, С. И.
Дуванова, О. В.
Селеменев, В. Ф.
Нгуен, А. Т.
Zyablov, A. N.
Govorukhin, S. I.
Duvanova, O. V.
Selemenev, V. F.
Nguen, A. T.
Issue Date: 2014
Publisher: Уральский федеральный университет
Citation: Проточно-инжекционное определение валина пьезокварцевым сенсором, модифицированным полимером с молекулярными отпечатками / А. Н. Зяблов, С. И. Говорухин, О. В. Дуванова [и др.] // Аналитика и контроль. — 2014. — № 4. — С. 438-441.
Abstract: Предложен способ определения валина в водных растворах с применением проточно-инжекционной системы, имеющей в качестве детектора пьезоэлектрический сенсор на основе полимера с молекулярными отпечатками (ПМО-Val). Диапазон определяемых концентраций валина составляет 10⁻¹-10⁻⁶ М, экспериментально установленный предел обнаружения - 10⁻⁵ М. Выявлены рабочие условия проточно-инжекционного определения валина в смесях с глутаминовой кислотой. Оценена способность пьезоэлектрического сенсора на основе полимера с молекулярными отпечатками к распознаванию валина в бинарных смесях с глутаминовой кислотой. Импринтинг-фактор для сенсора, модифицированного ПМО-Val, IF = 3.2. Рекомендуемый способ анализа характеризуется экспрессностью, небольшим расходом проб и реагентов, возможностью автоматизации измерений.
Flow-injection determination methods of analysis are gaining their popularity due to vast production of pure amino-acids and their quality control. This report describes methods of valine determination in aqueous solutions using a flow-injection system with piezoelectric sensor on the basis of molecular imprinted polymers (MIP) as a detector. To produce MIP polyamide acid was synthesized at 453 K directly on the surface of the sensor. The tamplate was removed without destruction of polymeric coating. Modified sensors MIP-Val were fit into a cell of original design. The speed of the eluent flow through the cell was 0.9 ml/min. The volume of the injected sample was 100 uL. The experimental part proved the ability of piezoelectric sensor modified with molecular imprinted polymer to determine valine in binary mixtures with glutamic acid. Detection limit of valine was 10⁻⁵ mol/L. The obtained data showed selectivity of piezoelectric sensor modified with (MIP) only to valine. Imprinting factor for the sensor modified with MIP-Val, IF =3.2
Keywords: VALINE
GLUTAMIC ACID
PIEZOELECTRIC SENSOR
MOLECULAR IMPRINTED POLYMERS (MIPS)
FLOWING-INJECTION ANALYSIS
ВАЛИН
ГЛУТАМИНОВАЯ КИСЛОТА
ПЬЕЗОЭЛЕКТРИЧЕСКИЙ СЕНСОР
ПОЛИМЕРЫ С МОЛЕКУЛЯРНЫМИ ОТПЕЧАТКАМИ
ПРОТОЧНО-ИНЖЕКЦИОННЫЙ АНАЛИЗ
URI: http://hdl.handle.net/10995/50265
RSCI ID: 22584555
ISSN: 2073-1442 (Print)
2073-1450 (Online)
Origin: Аналитика и контроль. 2014. № 4
Appears in Collections:Аналитика и контроль