Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/135835
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorМуратова, В. М.ru
dc.contributor.authorНехорошев, С. В.ru
dc.contributor.authorЛютикова, М. Н.ru
dc.contributor.authorГаджиева, А. С.ru
dc.contributor.authorMuratova, V. M.en
dc.contributor.authorNekhoroshev, S. V.en
dc.contributor.authorLiutikova, M. N.en
dc.contributor.authorGadzhiev, A. S.en
dc.date.accessioned2024-06-11T09:39:06Z-
dc.date.available2024-06-11T09:39:06Z-
dc.date.issued2023-
dc.identifier.citationОпределение карбонильных соединений и ионола в трансформаторном масле методом ИК-спектрометрии / В. М. Муратова, С. В. Нехорошев, М. Н. Лютикова, А. С. Гаджиева // Аналитика и контроль. — 2023. — Том 27. — № 4. — С. 219-229.ru
dc.identifier.issn2073-1450online
dc.identifier.issn2073-1442print
dc.identifier.urihttp://elar.urfu.ru/handle/10995/135835-
dc.description.abstractВ настоящее время трансформаторное масло наиболее широко используют как жидкий диэлектрик в высоковольтном оборудовании и особенно в силовых трансформаторах. Однако в процессе эксплуатации масло подвергается постепенному старению и его физико-химические свойства изменяются, что также приводит и к ухудшению изоляционных свойств. Поэтому основной задачей превентивной диагностики является контроль качества жидкого диэлектрика по некоторым параметрам, в том числе отслеживание изменения свойств трансформаторного масла происходят по расходованию антиокислительной присадки ионол, а также по накоплению окисленных соединений. Среди продуктов деструкции особое место занимают соединения кислотного характера (карбоновые кислоты, сложные эфиры, альдегиды, кетоны и др.). В настоящей работе предложена методика одновременного определения ионола и карбонильных соединений в масле в процессе его эксплуатации в высоковольтных трансформаторах. Методика базируется на ИК-спектрометрии. В отличие от традиционных методик определения ионола и кислотного числа, предлагаемая методика позволяет быстро и качественно получить более полную информацию о состоянии жидкого диэлектрика, а, следовательно, предпринять меры по улучшению его физико-химических и изоляционных свойств.ru
dc.description.abstractCurrently, transformer oil is the most widely used liquid dielectric in high-voltage equipment and especially in power transformers. However, in the process of operation oil undergoes gradual aging and physical and chemical properties of oil change resulting in deterioration of insulating properties. Therefore, the main task of preventive diagnostics is to control the quality of the liquid dielectric by some parameters, including tracking changes in the properties of the transformer oil by consumption of the antioxidant additive ionol, as well as by accumulation of oxidized compounds. Compounds of acidic nature (carboxylic acids, esters, aldehydes, ketones, etc.) occupy specific place among the degradation products. A method of simultaneous determination of ionol and carbonyl compounds in oil during its operation in high-voltage transformers is proposed in the present work. The technique is based on infrared spectrometry. Unlike the traditional methods of ionol and acid number determination, the proposed method allows quickly and qualitatively obtain more complete information about the state of liquid dielectric, and, consequently, to take measures for improving its physical, chemical and insulating properties.en
dc.description.sponsorshipИсследование выполнено при поддержке Фонда содействия инновациям-УМНИК №18599ГУ/2023.ru
dc.description.sponsorshipThe study was supported by the Innovation Promotion Fund - Umnik No. 18599GU/2023.en
dc.format.mimetypeapplication/pdfen
dc.language.isoruen
dc.publisherУральский федеральный университетru
dc.relation.ispartofАналитика и контроль. 2023. Том 27. № 4ru
dc.subjectМИНЕРАЛЬНОЕ ИЗОЛЯЦИОННОЕ МАСЛОru
dc.subjectТРАНСФОРМАТОРНОЕ МАСЛОru
dc.subjectАНТИОКИСЛИТЕЛЬНАЯ ПРИСАДКАru
dc.subjectИОНОЛ (2,6-ДИ-ТРЕТ-4-МЕТИЛФЕНОЛ)ru
dc.subjectКАРБОНИЛЬНЫЕ СОЕДИНЕНИЯru
dc.subjectПРОДУКТЫ ОКИСЛИТЕЛЬНОЙ ДЕСТРУКЦИИru
dc.subjectИК-СПЕКТРОМЕТРИЯru
dc.subjectMINERAL INSULATING OILen
dc.subjectTRANSFORMER OILen
dc.subjectANTIOXIDANT ADDITIVEen
dc.subjectIONOL (2,6-DI-TERT-4-METHYLPHENOL)en
dc.subjectCARBONYL COMPOUNDSen
dc.subjectOXIDATIVE DEGRADATION PRODUCTSen
dc.subjectIR SPECTROMETRYen
dc.titleОпределение карбонильных соединений и ионола в трансформаторном масле методом ИК-спектрометрииru
dc.title.alternativeDetermination of carbonyl compounds and ionol in transformer oil by IR spectrometryen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.rsi67353440-
dc.identifier.doi10.15826/analitika.2023.27.4.003-
local.description.firstpage219-
local.description.lastpage229-
local.issue4-
local.volume27-
Располагается в коллекциях:Аналитика и контроль

Файлы этого ресурса:
Файл Описание РазмерФормат 
aik_2023_27_4_005.pdf982,66 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.