Please use this identifier to cite or link to this item: http://elar.urfu.ru/handle/10995/133537
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRizvi, T.en
dc.contributor.authorDubey, S. P.en
dc.contributor.authorTripathi, N.en
dc.contributor.authorMakhija, S. P.en
dc.contributor.authorSingh, Mah.en
dc.contributor.authorSingh, Man.en
dc.date.accessioned2024-05-13T10:04:58Z-
dc.date.available2024-05-13T10:04:58Z-
dc.date.issued2024-
dc.identifier.citationFeasibility of FSPV-Grid Tied System in Urban Regions of Chhattisgarh State in India / Tanu Rizvi, Satya Prakash Dubey, Nagendra Tripathi, S. P. Makhija, Mahesh Singh, Mangal Singh // International Journal of Energy Production and Management. — 2024. — Vol. 9. Iss. 1. — P. 25-35.en
dc.identifier.issn2056-3280online
dc.identifier.issn2056-3272print
dc.identifier.urihttp://elar.urfu.ru/handle/10995/133537-
dc.descriptionReceived: 12 January 2024. Revised: 29 February 2024. Accepted: 8 March 2024. Available online: 31 March 2024.en
dc.description.abstractThis study presents a novel generation theory based on FSPV system together with grid integration in Chhattisgarh state. In this study four regions mainly two industries and two local loads have been chosen to evaluate the results. There is availability of nearby water sources at the selected sites. The technical, economical and environmental aspects of a proposed FSPV-grid tied system is analyzed in the same selected regions of Chhattisgarh and the results are compared with an existing grid-only system. The entire system of four major sites in the state are simulated using HOMER energy, powered by the National Renewable Energy Laboratory (NREL), United States. At the moment, all of the selected systems are powered by the grid-only system, and data has been collected for the same. The results of HOMER energy are further classified based on economic parameters such as NPC, LCOE, operating cost, system cost and paybacks. The second category includes technical parameters such as production proportion whereas, the third category includes environmental parameters of pollutants and water saving. The obtained results show that the FSPV-grid system as compared to grid-only system's NPC is reduced to 27%, 7.03%, 10.76%, 12.13%, LCOE is reduced to 69%, 27.8%, 44%, 44.6%, with paybacks of 10.11 years, 12.28 years, 11.99 years, and 12.21 years and IRRs of 8.8%, 7.7%, 8%, 7.7% respectively by following the production proportions of 77.7% and 22.3%, 54.2% and 45.8%, 65.2% and 34.8%, and 65% and 35% from FSPV and grid system, Also, CO2 emissions were reduced by 44.6%, 38.06%, 40.62%, and 41.23% compared to the gridonly system for all four selected sites in this study, which can help the attached industries and local loads gain carbon credit points.en
dc.language.isoenen
dc.publisherInternational Information and Engineering Technology Association (IIETA)en
dc.publisherUral Federal Universityen
dc.publisherУральский федеральный университетru
dc.relation.ispartofInternational Journal of Energy Production and Management. 2024. Vol. 9. Iss. 1en
dc.subjectFLOATING SOLAR PHOTOVOLTAIC (FSPV)en
dc.subjectGRIDen
dc.subjectLEVELIZED COST OF ENERGY (LCOE)en
dc.subjectNET PRESENT COST (NPC)en
dc.subjectCARBON DIOXIDE (CO2) EMISSIONen
dc.titleFeasibility of FSPV-Grid Tied System in Urban Regions of Chhattisgarh State in Indiaen
dc.typeArticleen
dc.identifier.rsihttps://www.elibrary.ru/item.asp?id=67216774-
dc.identifier.doi10.18280/ijepm.090104-
local.description.firstpage25-
local.description.lastpage35-
local.issue1-
local.volume9-
local.contributorRizvi, Tanuen
local.contributorDubey, Satya Prakashen
local.contributorTripathi, Nagendraen
local.contributorMakhija, S. P.en
local.contributorSingh, Maheshen
local.contributorSingh, Mangalen
Appears in Collections:International Journal of Energy Production and Management

Files in This Item:
File Description SizeFormat 
ijepm_2024_v9_1_04.pdf1,27 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.