Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://elar.urfu.ru/handle/10995/131609
Полная запись метаданных
Поле DC | Значение | Язык |
---|---|---|
dc.contributor | Калякин, Анатолий Сергеевич | ru |
dc.contributor.author | Kalyakin, A. S. | en |
dc.contributor.author | Volkov, A. N. | en |
dc.contributor.author | Gorshkov, M. Yu. | en |
dc.date.accessioned | 2024-04-08T12:02:20Z | - |
dc.date.available | 2024-04-08T12:02:20Z | - |
dc.date.issued | 2024 | - |
dc.identifier.citation | Kalyakin A. Stability and Reproducibility of Solid Electrolyte Amperometry Sensors at the Analysis of Hydrogen in Nitrogen-Containing Gas Mixtures / A. Kalyakin, A. Volkov, M. Gorshkov // Electrochemical Materials and Technologies. — 2024. — Vol. 3. № 1. — № 20243026. | en |
dc.identifier.issn | 2949-0561 | online |
dc.identifier.uri | http://elar.urfu.ru/handle/10995/131609 | - |
dc.description | Received: 9 November 2023. Accepted: 13 December 2023. Published online: 12 January 2024. | en |
dc.description.abstract | This paper illustrates the results of long-term tests on the stability of the output signal of the solid electrolyte amperometry sensor when measuring the hydrogen concentration in the H2 + N2 gaseous mixture. The obtained experimental data verify the stability and reproducibility of the sensor output signal for hydrogen concentration measurements in the nitrogen-containing gaseous mixture during > 8000 h of operation. The output signal drift, i.e., the limiting current value, was insignificant, less than ± 5 %. The sensor operation was performed at 3 temperature shifts with different time intervals; these changes did not have any impact either on the sensor integrity or on its operation. The structure of the solid electrolyte sensor, intermediate solid electrolyte / electrode layer and electrodes did not undergo any significant changes during operation. The dynamic characteristics of the sensor, the response time in particular, remained stable during the operation. | en |
dc.description.sponsorship | The present research was performed within the budget plan of the Institute of High Temperature Electrochemistry. | en |
dc.language.iso | en | en |
dc.publisher | Уральский федеральный университет | ru |
dc.publisher | Ural Federal University | en |
dc.relation.ispartof | Electrochemical Materials and Technologies. 2024. Vol. 3. № 1 | en |
dc.subject | HYDROGEN | en |
dc.subject | SOLID ELECTROLYTE | en |
dc.subject | SENSOR | en |
dc.subject | STABILITY | en |
dc.subject | LIMITING CURRENT | en |
dc.subject | RESPONSE TIME | en |
dc.title | Stability and Reproducibility of Solid Electrolyte Amperometry Sensors at the Analysis of Hydrogen in Nitrogen-Containing Gas Mixtures | en |
dc.type | Article | en |
dc.identifier.rsi | https://www.elibrary.ru/item.asp?id=65429131 | - |
dc.identifier.doi | 10.15826/elmattech.2024.3.026 | - |
local.issue | 1 | - |
local.volume | 3 | - |
local.description.order | 20243026 | - |
local.contributor | Kalyakin, Anatoly S. | en |
local.contributor | Volkov, Aleksander N. | en |
local.contributor | Gorshkov, Maxim Yu. | en |
local.contributor | Горшков, Максим Юрьевич | ru |
local.contributor | Калякин, Анатолий Сергеевич | ru |
Располагается в коллекциях: | Electrochemical Materials and Technologies |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
emt_2024_v3_1_01.pdf | 496,16 kB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.