Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://elar.urfu.ru/handle/10995/127291
Название: | Effect of Operational Parameters on Anaerobic Digestion of Municipal and Sugar Industry Wastewater |
Авторы: | Devona Sathiyah Lindokuhle Ngema Emmanuel Kweinor Tetteh Martha Noro Chollom Sudesh Rathilal |
Дата публикации: | 2023 |
Издатель: | International Information and Engineering Technology Association (IIETA) Ural Federal University Уральский федеральный университет |
Библиографическое описание: | Effect of Operational Parameters on Anaerobic Digestion of Municipal and Sugar Industry Wastewater / Devona Sathiyah, Lindokuhle Ngema, Emmanuel Kweinor Tetteh, Martha Noro Chollom, Sudesh Rathilal // International Journal of Energy Production and Management. — 2023. — Vol. 8. Iss. 3. — P. 161-167. |
Аннотация: | Anaerobic digestion (AD) is a versatile process that entails low energy consumption and has low capital costs. Unfortunately, this process is not widely commercialized due to instabilities. The instability in the system is due to variations in the feedstock, operating, and environmental conditions. Therefore, this study aimed to determine the effect of organic loading rate (OLR), temperature, and pH on the AD system. An online pH and temperature monitoring sensor calibration were also studied to adjust AD parameters. The water quality parameters that were monitored were turbidity, chemical oxygen demand (COD), and colour. Wastewater with a low and high organic loading had a 90% and 36% COD reduction respectively after 5 days. Without pH adjustment, the pH of the system was 4.1 to 4.4 and the maximum COD reduction was 56.2%. When the pH was increased to 6.8, the maximum COD reduction was 66.5%. For the unadjusted temperature (room temperature), a maximum COD reduction of 56% was achieved. When the temperature was increased to 40℃, the maximum COD reduction was 66%. The increase in pH and temperature resulted in a 10% increase in COD reduction in the AD system. From the study, online pH, and temperature sensor calibrations errors were found to be 0.5 and 0.05 respectively as compared with the manual analytical technique. One of the limitations of this study was obtaining the apparatus to control temperature and pH at the same time. Future research will involve the automation of the AD system will the determined optimum conditions. This suggests smart monitoring and control sensors of AD operational parameters can repurpose its reliability for commercial activity. |
Ключевые слова: | ANAEROBIC DIGESTION ORGANIC LOADING RATE PH ADJUSTMENT TEMPERATURE CONTROL SMART SYSTEMS SENSOR CALIBRATION MONITORING |
URI: | http://elar.urfu.ru/handle/10995/127291 |
Идентификатор РИНЦ: | https://elibrary.ru/item.asp?id=54655924 |
ISSN: | 2056-3272 2056-3280 |
DOI: | 10.18280/ijepm.080304 |
Сведения о поддержке: | The authors wish to thank the Durban University of Technology, the Green Engineering Research Group, and the South African Water Research Commission (WRC Project: C2021/2022-00958). |
Источники: | International Journal of Energy Production and Management. 2023. Vol. 8. Iss. 3 |
Располагается в коллекциях: | International Journal of Energy Production and Management |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
ijepm_2023_v8_3_04.pdf | 1,41 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.