Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/121277
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorСорвин, М. И.ru
dc.contributor.authorСавельев, А. А.ru
dc.contributor.authorСтойков, И. И.ru
dc.contributor.authorБелякова, С. В.ru
dc.contributor.authorЕвтюгин, Г. А.ru
dc.contributor.authorSorvin, M. I.en
dc.contributor.authorSaveliev, A. A.en
dc.contributor.authorStoikov, I. I.en
dc.contributor.authorBelyakova, S. V.en
dc.contributor.authorEvtugyn, G. A.en
dc.date.accessioned2023-02-20T08:17:30Z-
dc.date.available2023-02-20T08:17:30Z-
dc.date.issued2022-
dc.identifier.citationТвердоконтактные потенциометрические сенсоры на основе наночастиц серебра в супрамолекулярной матрице для определения галогенид-ионов / М. И. Сорвин, А. А. Савельев, И. И. Стойков, С. В. Белякова, Г. А. Евтюгин // Аналитика и контроль. — 2022. — Том 26. — № 3. — С. 193-203. — DOI: 10.15826/analitika.2022.26.3.002ru
dc.identifier.issn2073-1450online
dc.identifier.issn2073-1442print
dc.identifier.otherhttps://journals.urfu.ru/index.php/analitika/article/view/6299-
dc.identifier.urihttp://elar.urfu.ru/handle/10995/121277-
dc.description.abstractОпределение содержания галогенид-ионов в лекарственных препаратах и водах различного назначения представляет собой актуальную задачу современной аналитической химии. В работе представлен твердоконтактный потенциометрический сенсор на основе стеклоуглеродного электрода, покрытого слоем электрополимеризованного анилина и суспензией наночастиц серебра в матрице производного тиакаликс[4]арена с концевыми пирокатехиновыми группами. Суспензию получали, химически восстанавливая ионы серебра тиакаликс[4]ареном и капельно наносили на слой полианилина. Сенсор демонстрировал потенциометрический отклик на хлорид-, бромид и йодид-ионы. Для одновременного определения йодид- и бромид ионов предложено использовать мультисенсорную систему из четырех электродов, отличающихся составом и объемом суспензии, наносимой на полимерную подложку полианилина. На выборке смесей йодид- и бромид-ионов показана возможность предсказания отклика на основе простой аддитивной модели. Аналогичным образом проводили одновременное определение обоих ионов в смесях произвольного состава. Мультисенсорная система была апробирована на определении йодид-ионов в йодсодержащих медицинских препаратов, а также йодид- и бромид-ионов в искусственных образцах минеральной воды. Методом сравнения выступала ионная хроматография. Сенсоры позволяют проводить определение от 0.1 мкМ до 10 мМ йодид- и бромид-ионов в смесях. Предложенный подход и твердоконтактные потенциометрические сенсоры могут найти применение в анализе ионного состава вод и контроля производства и хранения лекарственных препаратов.ru
dc.description.abstractDetermination of halogenide ions in pharmaceuticals and various waters is an actual task for the modern analytical chemistry. In the current work, solid-contact potentiometric sensor, based on the glassy carbon electrode covered with the layer of electropolymerized polyaniline and suspension of silver nanoparticles in the matrix of thiacalix[4]arene derivative bearing terminal catechol groups, has been described. The suspension was obtained by the chemical reduction of silver ions with the thiacalix[4]arene and drop casted on the polyaniline layer. The sensor showed potentiometric response to chloride-, bromide and iodide ions. For the simultaneous determination of iodide and bromide ions, a multi-sensor system, consisting of four electrodes with the different volumes of the suspension placed on the polyaniline layer, has been developed. The possibility of the response prediction within the simple additive model was found for the set of the iodide and bromide mixtures. In a similar manner, simultaneous determination of both ions in the variable mixtures has been performed. The multi-sensor system was tested during the determination of iodides in iodine containing pharmaceuticals and the determination of iodide and bromide ions in the artificial mineral water samples. Ionic chromatography was chosen as the comparison method. Sensors made it possible to determine from 0.1 μM to10 mMiodide and bromide ions in mixtures. The proposed approach and solid-contact potentiometric sensors can be used in the analysis of ion content of the waters and in control of the production and storage conditions of pharmaceuticals.en
dc.description.sponsorshipРабота выполнена за счет средств субсидии, выделенной Казанскому федеральному университету для выполнения государственного задания в сфере научной деятельности № 0671-2020-0063.ru
dc.description.sponsorshipThis work was funded by the subsidy allocated to Kazan Federal University for the state assignment in the sphere of scientific activities (grant No 0671-2020-0063).en
dc.format.mimetypeapplication/pdfen
dc.language.isoruen
dc.publisherУральский федеральный университетru
dc.relation.ispartofАналитика и контроль. 2022. Том 26. № 3ru
dc.subjectТВЕРДОКОНТАКТНЫЙ СЕНСОРru
dc.subjectИОНОМЕТРИЯru
dc.subjectОПРЕДЕЛЕНИЕ ГАЛОГЕНИДОВru
dc.subjectПОЛИАНИЛИНru
dc.subjectМУЛЬТИСЕНСОРНАЯ СИСТЕМАru
dc.subjectАДДИТИВНАЯ МОДЕЛЬ ОТКЛИКАru
dc.subjectSOLID-CONTACT SENSORen
dc.subjectIONOMETRYen
dc.subjectHALOGENIDE DETERMINATIONen
dc.subjectPOLYANILINEen
dc.subjectMULTISENSORY SYSTEMen
dc.subjectADDITIVE MODEL OF THE RESPONSEen
dc.titleТвердоконтактные потенциометрические сенсоры на основе наночастиц серебра в супрамолекулярной матрице для определения галогенид-ионовru
dc.title.alternativeSolid-contact potentiometric sensors based on silver nanoparticles in the supramolecular matrix for the determination of halogenide ionsen
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.rsi49595955-
dc.identifier.doi10.15826/analitika.2022.26.3.002-
dc.identifier.scopus85142614719-
local.description.firstpage193-
local.description.lastpage203-
local.issue3-
local.volume26-
local.identifier.eid2-s2.0-85142614719-
Располагается в коллекциях:Аналитика и контроль

Файлы этого ресурса:
Файл Описание РазмерФормат 
aik_2022_26_3_004.pdf1,19 MBAdobe PDFПросмотреть/Открыть