Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/64939
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorSilbermann, V.en
dc.date.accessioned2018-11-21T12:57:00Z-
dc.date.available2018-11-21T12:57:00Z-
dc.date.issued2018-
dc.identifier.citationSilbermann V. The behavior of single-shaft combined cycle gas turbine units at frequency drop in the connected grid / Viktor Silbermann // International Journal of Energy Production and Management. — 2018. — Vol. 3. Iss. 3. — P. 237-243.en
dc.identifier.issn2056-3272 (paper format)-
dc.identifier.issn2056-3280 (online)-
dc.identifier.urihttp://elar.urfu.ru/handle/10995/64939-
dc.description.abstractIn the last 15 years many companies have developed single-shaft combined cycle gas turbine (CCGT) units having one generator, which is coupled to common single shaft of gas turbine (GT) and steam turbine (ST) via a special elaborated synchro-self-shifting (SSS) clutch. This clutch connects automatically the drive of the ST at one end of the generator to complement the drive of the GT at the other end of the generator. Such a technical solution, in comparison to previous ones, allows economizing on one generator circuit breaker (GCB) as well as the use of a two-winding transformer instead of a three-winding transformer. This scheme of single-shaft CCGT units is taking place in many countries, but cases of tripping of such units by surge protection of GT have been observed in any power plants (PP). All such trippings were accompanied by frequency drop in the high voltage (HV) grid, to which these units were connected, although these drops were within the permissible limits for the CCGT units. This paper reports the results of investigating one of these cases of tripping, discusses the possible cause of these incidents and elaborates on some measures to prevent such trippings in the future.en
dc.format.mimetypeapplictaion/pdfen
dc.language.isoenen
dc.publisherUral Federal Universityen
dc.publisherWIT Pressen
dc.publisherУральский федеральный университетru
dc.relation.ispartofInternational Journal of Energy Production and Management. 2018. Vol. 3. Iss. 3en
dc.subjectCCGT UNITen
dc.subjectDISTURBANCES IN THE HV GRIDen
dc.subjectFREQUENCY DROPen
dc.subjectSSS CLUTCHen
dc.subjectSTEAM TURBINE ACCELERATIONen
dc.subjectSURGE PROTECTIONen
dc.subjectWATER PUMPS’ DRIVESen
dc.titleThe behavior of single-shaft combined cycle gas turbine units at frequency drop in the connected griden
dc.typeArticleen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeinfo:eu-repo/semantics/publishedVersionen
dc.identifier.rsihttps://elibrary.ru/item.asp?id=36430476-
dc.identifier.doi10.2495/EQ-V3-N3-237-243-
local.description.firstpage237-
local.description.lastpage243-
local.issue3-
local.volume3-
Располагается в коллекциях:International Journal of Energy Production and Management

Файлы этого ресурса:
Файл Описание РазмерФормат 
ijepm_2018_v3_3_07.pdf1,19 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.