Название: Evaluation of the Operating Modes of the Urban Electric Networks in Dushanbe City, Tajikistan
Авторы: Tavarov, S. S.
Zicmane, I.
Beryozkina, S.
Praveenkumar, S.
Safaraliev, M.
Shonazarova, S.
Дата публикации: 2022
Издатель: MDPI
Библиографическое описание: Tavarov, SS, Zicmane, I, Beryozkina, S, Praveenkumar, S, Safaraliev, M & Shonazarova, S 2022, 'Evaluation of the Operating Modes of the Urban Electric Networks in Dushanbe City, Tajikistan', Inventions, Том. 7, № 4, 107. https://doi.org/10.3390/inventions7040107
Tavarov, S. S., Zicmane, I., Beryozkina, S., Praveenkumar, S., Safaraliev, M., & Shonazarova, S. (2022). Evaluation of the Operating Modes of the Urban Electric Networks in Dushanbe City, Tajikistan. Inventions, 7(4), [107]. https://doi.org/10.3390/inventions7040107
Аннотация: Currently, energy saving has become an acute problem all over the world. Due to the rapid development of both the energy and information technology sectors, as well as an increase in the electricity demand, the electric distribution system is facing problems caused by stricter requirements for electricity quality, reliability, efficiency, and sustainability. Therefore, the use of energy-saving technologies, both the improvement of existing ones and the application of new ones, is one of the main reserves for electricity saving in power supply systems. This study is devoted to the evaluation of the operating modes of transformer substations of the 6–10 kV electric distribution network in Dushanbe city, based on the results of control winter measurements and the dependence of the low coefficient of active power in transformer substations. It has been observed that, with a low coefficient of active power in transformer substations, when transmitting electricity from substation busbars to transformer substations of a final consumer via overhead transmission lines (an average length of 5 km), the voltage loss exceeds the maximum permissible values. When transmitting electricity via cable lines, the voltage losses are within the limit of 5%. However, a low active power factor may be the reason for an increase in capacitive currents, followed by the command of single-phase earth fault currents. Due to the low active power factor, the increase in voltage losses and useful power losses leads to the inefficient operating modes of the transformer substations. © 2022 by the authors.
Ключевые слова: ACTIVE POWER FACTOR
NATURE OF LOADS
REACTIVE POWER CONSUMPTION
URBAN ELECTRIC NETWORKS
VOLTAGE LOSSES
URI: http://elar.urfu.ru/handle/10995/131240
Условия доступа: info:eu-repo/semantics/openAccess
cc-by
Текст лицензии: https://creativecommons.org/licenses/by/4.0/
Идентификатор SCOPUS: 85144680987
Идентификатор WOS: 000900850200001
Идентификатор PURE: 33222773
f505da11-f58a-4117-b0fb-f4daeca3690e
ISSN: 2411-5134
DOI: 10.3390/inventions7040107
Сведения о поддержке: Ministry of Education and Science of the Russian Federation, Minobrnauka, (FEUZ-2022-0031)
The research funding from the Ministry of Science and Higher Education of the Russian Federation (Ural Federal University Program of Development within the Priority-2030 Program) is gratefully acknowledged: Grant number FEUZ-2022-0031.
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85144680987.pdf1,51 MBAdobe PDFПросмотреть/Открыть


Лицензия на ресурс: Лицензия Creative Commons Creative Commons