Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://elar.urfu.ru/handle/10995/118338
Название: A rapid and direct method for half value layer calculations for nuclear safety studies using MCNPX Monte Carlo code
Авторы: Tekin, H. O.
ALMisned, G.
Issa, S. A. M.
Zakaly, H. M. H.
Дата публикации: 2022
Издатель: Korean Nuclear Society
Библиографическое описание: A rapid and direct method for half value layer calculations for nuclear safety studies using MCNPX Monte Carlo code / H. O. Tekin, G. ALMisned, S. A. M. Issa et al. // Nuclear Engineering and Technology. — 2022. — Vol. 54. — Iss. 9. — P. 3317-3323.
Аннотация: Half Value Layer calculations theoretically need prior specification of linear attenuation calculations, since the HVL value is derived by dividing ln(2) by the linear attenuation coefficient. The purpose of this study was to establish a direct computational model for determining HVL, a vital parameter in nuclear radiation safety studies and shielding material design. Accordingly, a typical gamma-ray transmission setup has been modeled using MCNPX (version 2.4.0) general-purpose Monte Carlo code. The MCNPX code's INPUT file was designed with two detection locations for primary and secondary gamma-rays, as well as attenuator material between those detectors. Next, Half Value Layer values of some well-known gamma-ray shielding materials such as lead and ordinary concrete have been calculated throughout a broad gamma-ray energy range. The outcomes were then compared to data from the National Institute of Standards and Technology. The Half Value Layer values obtained from MCNPX were reported to be highly compatible with the HVL values obtained from the NIST standard database. Our results indicate that the developed INPUT file may be utilized for direct computations of Half Value Layer values for nuclear safety assessments as well as medical radiation applications. In conclusion, advanced simulation methods such as the Monte Carlo code are very powerful and useful instruments that should be considered for daily radiation safety measures. The modeled MCNPX input file will be provided to the scientific community upon reasonable request. © 2022 Korean Nuclear Society
Ключевые слова: HALF VALUE LAYER
MCNPX
MONTE CARLO SIMULATIONS
RADIATION SAFETY
URI: http://elar.urfu.ru/handle/10995/118338
Условия доступа: info:eu-repo/semantics/openAccess
Идентификатор SCOPUS: 85128259113
Идентификатор WOS: 000862955100014
Идентификатор PURE: 30848997
ISSN: 17385733
DOI: 10.1016/j.net.2022.03.037
Сведения о поддержке: Princess Nourah Bint Abdulrahman University, PNU: PNURSP2022R149
This work was performed under Princess Nourah bint Abdulrahman University Researchers Supporting Project Number (PNURSP2022R149), Princess Nourah bunt Abdulrahman University, Riyadh, Saudi Arabia. The authors express their sincere gratitude to Princess Nourah bint Abdulrahman University.
Располагается в коллекциях:Научные публикации ученых УрФУ, проиндексированные в SCOPUS и WoS CC

Файлы этого ресурса:
Файл Описание РазмерФормат 
2-s2.0-85128259113.pdf1,97 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.